- 78 -
- 79 -
ST
AND UNIT
SCREEN C
ONFIG'
GRAPHIC C
ONFIG'
FRAME INS
TALL'
SENSOR C
ONFIG'
OPERA
TION
W
ALL UNIT
OPE-11701
Innovative e-Board of New Conception
e-Board
1
2
5
.
5
. Install the second MPDP set
y
Put the second MPDP set at the upper center position.
y
Insert the PEGs into the PEG holes of the upper center MAIN FRAME and down the set slowly.
y
Be careful not to give any impact to the set to prevent the damage for the MPDP panel.
st
nd
GUIDE PIN
1
2
5
.
6
. Position the first and the second MPDP sets closely.
y
Turn the ADJUSTER at the rear side of the upper center MAIN FRAME with the
8
mm Allen Wrench to make the
MPDP sets contact with each other closely.
st
nd
ADJUSTER
ID :
5
ID :
5
ID :
2
ID :
2
All the connection cables
should be connected prior to
MPDP installation.
Check the MPDP ID numbers
before the installation.
Turn the ADJUSTER at the rear side of the
upper center MAIN FRAME to position the
MPDP sets contact with each other closely.
Turn the ADJUSTERs in the both sides until
the GUIDE PINs enter into the GUIDE PIN
holes and MPDP sets contact with each
other closely.
Turn the ADJUSTER at the rear bottom
side of each MAIN FRAME with an
8
mm
Allen Wrench to higher or lower it.
ADJUSTER
(M
10
*
50
)
WARNING
• Be careful not to give any impact to the set to prevent the damage for
the MPDP panel.
There is a gap between the MPDP sets by
the height difference of ADJUSTER.
It prevents the damages on the MPDP sets
from the installation impact.