![Orion OPE-11701 Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/orion/ope-11701/ope-11701_user-manual_1652566044.webp)
- 84 -
- 85 -
ST
AND UNIT
SCREEN C
ONFIG'
GRAPHIC C
ONFIG'
FRAME INS
TALL'
SENSOR C
ONFIG'
OPERA
TION
W
ALL UNIT
OPE-11701
Innovative e-Board of New Conception
e-Board
GUIDE PIN
Fixed Center Column
5
.
11
. Assemble the GUIDE PINs on the side of MPDP sets.
y
Insert the GUIDE PINs at the
8
positions on the side of MPDP sets
6
. MPDP Alignment
6
.
1
. Adjust the horizontality of the Fixed Center Column.
y
Put a spirit level on the top of the MASTER FRAME in the Fixed Center Column.
y
Turn the ADJUSTER at the rear side of the lower MAIN FRAME with the
8
mm Allen Wrench to adjust the
horizontality.
Turn the ADJUSTER of the lower MAIN
FRAME with the
8
mm Allen Wrench to
adjust the horizontality.
SPIRIT LEVEL
Turn the ADJUSTER at the rear bottom
side of each MAIN FRAME with an
8
mm
Allen Wrench to higher or lower it.
ADJUSTER
(M
10
*
50
)