PART 3: CX-Server Runtime
OMRON
CHAPTER 1 - Technical Specification
CX-Server Runtime_Page 3
Communications Requirements
In order to use serial communication types SYSMAC WAY and Toolbus the following is required:
♦
RS232 connection via a standard serial port on the PC (COM1 etc.) or RS422 connection to a 422 serial
board.
♦
In order to use SYSMAC LINK directly from the PC a SYSMAC LINK Network Service Board and
FinsGateway Version 3 or higher is required.
♦
In order to use SYSMAC NET directly from the PC a SYSMAC NET Network Service Board and
FinsGateway Version 3 are required. (Windows NT4 only)
♦
In order to use Controller Link directly from the PC a Controller Link Network Service Board (wired or
optical) and FinsGateway Version 3 or higher are required.
♦
In order to use Ethernet an Ethernet card, Windows Sockets software and TCP/IP must be installed and
configured.
♦
In order to use an ISA board FinsGateway Version 3 or higher is required.
♦
Controller link PC NSB is supported using FinsGateway Version 3 or higher.
♦
SYSMAC LINK PC NSB is supported using FinsGateway Version 3 or higher.
In order to use FINSGateway with the CLK/SLK PCI board in the Windows 98 or 2000 operating system the
appropriate drivers must be installed. These drivers can be found on the CX-Server CD under:
CX-
Server\WDM\CLK (PCI)\ or CX-Server\WDM\SLK (PIC)\
Refer to
Chapter 3- Communications
for more information and the appropriate hardware system manuals for
full information about connecting and configuring these devices for the environment.
Installation
This describes the procedures involved in the installation of CX-Server on a standard workstation running
Microsoft Windows 95, 98, Millennium, 2000 or XP and NT4.0 with Service Pack 5 or later.
The software is supplied on CD-ROM and is installed easily from within Microsoft Windows. The installation
can be terminated at any point during the installation process.
If CX-Server is being installed as part of the CX-Programmer installation then on completion of the CX-
Programmer installation a number of dialogs will prompt for information concerning the installation of CX-
Server and its components.
Note:
If using CX-Server under Windows 95, DCOM95 is required for correct operation. This is
installed as part on the install process.
1, 2, 3…
1.
Insert the CD-ROM in the appropriate drive and select the
Run
option from the
Start
pushbutton on the taskbar.
2. Click
the
Browse
pushbutton and select the Setup.exe executable file in the CX-Server
directory or from the CD-ROM drive.
3. Click
the
OK
pushbutton to start the installation then follow the on-screen instructions.
Starting CX-Server
CX-Server components are normally accessed from the invoking application. However, a number of tools can
be accessed as stand-alone tools from the windows
Start
menu (on the Microsoft Windows taskbar).
Performance Monitor tool.
DDE Manager tool.
CX-Server Import / Export tool.
Help and How to Access it
CX-Server comes with a detailed context-sensitive help system. At any time while using the software, it is
possible to get help on the particular point that is currently being worked on, or on general aspects of CX-Server.
This system is intended to complement the manual, by providing online reference to specific functions of the
Содержание Sysmac WS02-CXPC1-EV3
Страница 1: ...Cat No W414 E1 01 SYSMAC...
Страница 2: ......
Страница 3: ...SYSMAC WS02 CXPC1 EV3 CX Programmer Ver 3 1 Operation Manual Revised November 2002...
Страница 4: ......
Страница 6: ......
Страница 7: ...PART1 CX Programmer...
Страница 8: ......
Страница 24: ......
Страница 34: ......
Страница 106: ......
Страница 130: ......
Страница 131: ...PART 2 CX Server PLC Tools...
Страница 132: ......
Страница 136: ......
Страница 158: ......
Страница 168: ......
Страница 194: ......
Страница 206: ......
Страница 250: ......
Страница 298: ......
Страница 304: ......
Страница 305: ...PART 3 CX Server Runtime...
Страница 306: ......
Страница 310: ......
Страница 338: ......
Страница 344: ......
Страница 378: ......
Страница 384: ......
Страница 388: ......
Страница 390: ...Cat No W414 E1 01 Note Specifications subject to change without notice Printed in Japan Authorized Distributor...