PART 2: CX-Server PLC Tools
OMRON
CHAPTER 8 – CX-Net Network Configuration Tool
CX-Server PLC Tools_ Page 61
1, 2, 3…
1. Click on the Save As pushbutton in the Data Link Setup dialogue. The Save As
dialogue is displayed.
2.
Enter the new file name for the data link table (ensure that the file type is correct) in the
File name field.
3.
Either select the
Save
pushbutton to save the new file and return to the previous dialogue
or select the
Cancel
to abort the operation.
Deleting a Table in a PLC
The current Data Link table held in the PLC can be deleted by selecting the
Delete
pushbutton.
Viewing Table Information
The Table Information dialogue displays basic information relating to the selected Data Link table indicating the
author, associated network and file name. The information displayed on this screen cannot be edited whilst
online. Use the following procedure to view table information.
1, 2, 3…
1. Select
the
Info
pushbutton on the Data Link Setup dialogue.
2. Select
the
Close
pushbutton to remove the dialogue from the screen. The Data Link
Table dialogue is redisplayed.
Select the
New
pushbutton in the dialogue to clear the dialogue information.
Offline SYSMAC NET Data Link Editor
The SYSMAC NET Data Link Table Editor is available to both CV-series and C-series PLCs linked to a
SYSMAC NET unit.
The status bar provides instant help.
Access to the SYSMAC NET Data Link Editor dialogue is achieved in a number of ways:
♦
From the CX-Net Network Configuration tool. Select Editor from the Data Link menu.
The Select New File type dialogue is displayed. Select the SYSMAC NET file type
from the File Type field and select the OK pushbutton.
♦
From the Data Link Setup dialogue. Select the Edit pushbutton.
♦
From the Start pushbutton in the Microsoft Windows taskbar. The Select New File type
dialogue is displayed. Select the SYSMAC NET file type from the
File Type
field and
select the
OK
pushbutton.
Creating and Editing a SYSMAC NET Data Link Table Item
Use the following procedure to creates SYSMAC NET Data Link Table Item.
1, 2, 3…
1. Select
the
New
button from the toolbar in the SYSMAC NET Data Link Table Editor
dialogue.
2. Select
the
Insert Table Item
option from the
Table
menu. Address information can also
be edited by double-clicking on the required node.
Содержание Sysmac WS02-CXPC1-EV3
Страница 1: ...Cat No W414 E1 01 SYSMAC...
Страница 2: ......
Страница 3: ...SYSMAC WS02 CXPC1 EV3 CX Programmer Ver 3 1 Operation Manual Revised November 2002...
Страница 4: ......
Страница 6: ......
Страница 7: ...PART1 CX Programmer...
Страница 8: ......
Страница 24: ......
Страница 34: ......
Страница 106: ......
Страница 130: ......
Страница 131: ...PART 2 CX Server PLC Tools...
Страница 132: ......
Страница 136: ......
Страница 158: ......
Страница 168: ......
Страница 194: ......
Страница 206: ......
Страница 250: ......
Страница 298: ......
Страница 304: ......
Страница 305: ...PART 3 CX Server Runtime...
Страница 306: ......
Страница 310: ......
Страница 338: ......
Страница 344: ......
Страница 378: ......
Страница 384: ......
Страница 388: ......
Страница 390: ...Cat No W414 E1 01 Note Specifications subject to change without notice Printed in Japan Authorized Distributor...