The Setup Group within the Programming Mode
In Setup Group, the user can access the minimum group of parameters required to operate the application.
Note:
Setup Group parameters are listed in
Table 4.4
.
Figure 4.5
illustrates the keys to press to enter the Setup Group.
In this example, the source of the frequency reference is changed from the control circuit terminals to the LED Operator
(i.e., b1-01 is changed from 1 to 0).
STOP
STOP
STOP
STOP
STOP
(2x)
<1> Move to the right to change parameter settings. Scroll
down to view and check settings in the Setup Mode.
<2> To return to the Top Menu, press . To view or edit
other parameters, press and .
Control Circuit
Terminal
Select digit
to edit
Parameter Display
LED Operator
Frequency reference
appears when powered up
Parameter Display
Press until
appears
<1>
<2>
Figure 4.5 Setup Group Example
u
Changing Parameter Settings or Values
This example explains changing C1-01 (Acceleration Time 1) from 10.0 seconds (default) to 20.0 seconds.
Step
Display/Result
1.
Turn on the power to the drive. The initial display appears.
2.
Press the
key until the Setup Mode Screen appears.
3.
Press the
key to view the parameter setting display.
4.
Scroll through parameters by pressing the
key until C1-01 appears.
5.
Press
to view the current setting value (10.0). (Number farthest to the left flashes)
6.
Press
until the desired number is selected. (“1” flashes)
7.
Press the
key and enter 0020.0.
8.
Press
and the drive will confirm the change.
9.
The display automatically returns to the screen shown in Step 4.
10.
Press the
key until back at the initial display.
u
Verifying Parameter Changes: Verify Menu
The Verify Menu lists edited parameters from the Programming Mode. The Verify Menu helps determine which settings
have been changed, and is particularly useful when replacing a drive. If no settings have been changed the Verify Menu
will read
. The Verify menu also allows users to access and re-edit edited parameters.
Note:
The Verify Menu will not display parameters from the A1 group even if those parameters have been changed from default settings.
4.3 The Drive and Programming Modes
SIEP C710606 33A OYMC AC Drive – J1000 User Manual
59
4
Start-Up Programming & Operation
Содержание JZA
Страница 2: ......
Страница 24: ...1 3 Component Names This Page Intentionally Blank 22 SIEP C710606 33A OYMC AC Drive J1000 User Manual...
Страница 52: ...3 12 Wiring Checklist This Page Intentionally Blank 50 SIEP C710606 33A OYMC AC Drive J1000 User Manual...
Страница 70: ...4 9 Test Run Checklist This Page Intentionally Blank 68 SIEP C710606 33A OYMC AC Drive J1000 User Manual...
Страница 162: ...8 5 Communication Options This Page Intentionally Blank 160 SIEP C710606 33A OYMC AC Drive J1000 User Manual...
Страница 210: ...C 13 Self Diagnostics This Page Intentionally Blank 208 SIEP C710606 33A OYMC AC Drive J1000 User Manual...
Страница 230: ...Index This Page Intentionally Blank 228 SIEP C710606 33A OYMC AC Drive J1000 User Manual...
Страница 231: ...This Page Intentionally Blank SIEP C710606 33A OYMC AC Drive J1000 User Manual 229...