No.
Name
Description
Range
Def.
Mode
Addr.
Hex
Pg.
b2-03
DC Injection
Braking Time/DC
Excitation Time at
Start
Sets DC Injection Braking time at start. Disabled when set to 0.00
seconds.
0.00 to
10.00
0.00 s
O
18B
76
b2-04
DC Injection
Braking Time at
Stop
Sets DC Injection Braking time at stop.
When b1-03 = 0, this parameter sets the amount of DC Injection
time applied to the motor at the end of the decel ramp. Disabled
when set to 0.00.
0.00 to
10.00
0.50 s
O
18C
76
u
C: Tuning
C parameters are used to adjust the acceleration and deceleration times, S-curves, slip and torque compensation functions
and carrier frequency selections.
No.
Name
Description
Range
Def.
Mode
Addr.
Hex
Pg.
C1: Acceleration and Deceleration Times
Use C1 parameters to configure motor acceleration and deceleration.
C1-01
<22>
Acceleration Time
1
Sets the time to accelerate from 0 to maximum frequency.
0.0 to
6000.0
10.0 s
S
200
77
C1-02
<22>
Deceleration Time
1
Sets the time to decelerate from maximum frequency to 0.
S
201
77
C1-03
<22>
Acceleration Time
2
Sets the time to accelerate from 0 to maximum frequency when
Accel/Decel times 2 are selected by a digital input.
O
202
77
C1-04
<22>
Deceleration Time
2
Sets the time to decelerate from maximum frequency to 0 when
Accel/Decel times 2 are selected by a digital input.
O
203
77
C1-09
Fast-Stop Time
Sets the time to decelerate from maximum frequency to 0 for the
multi-function input fast-stop function.
Note:
This parameter is also used by selecting “Fast-Stop” as a Stop
Method when a fault is detected.
O
208
77
C2: S-Curve Characteristics
Use C2 parameters to configure S-curve operation.
C2-01
S-Curve
Characteristic at
Accel Start
The S-curve can be controlled in the four points shown below.
Run
command
Output
frequency
Time
C2-01
C2-04
C2-02
C2-03
ON
OFF
S-curve is used to further soften the starting and stopping ramp. The
longer the S-curve time, the softer the starting and stopping ramp.
0.00 to
10.00
0.20 s
O
20B
78
C2-02
S-Curve
Characteristic at
Accel End
0.00 to
10.00
0.20 s
O
20C
78
C2-03
S-Curve
Characteristic at
Decel Start
0.00 to
10.00
0.20 s
O
20D
78
C2-04
S-Curve
Characteristic at
Decel End
0.00 to
10.00
0.00 s
O
20E
78
C3: Slip Compensation
Use C3 parameters to configure the slip compensation function.
C3-01
<22>
Slip Compensation
Gain
Sets the slip compensation gain. Decides for what amount the output
frequency is boosted in order to compensate the slip.
Note:
Adjustment is not normally required.
0.0 to 2.5
0.0
O
20F
78
C3-02
Slip Compensation
Primary Delay
Time
Adjusts the slip compensation function delay time.
Decrease the setting when the slip compensation response is too
slow, increase it when the speed is not stable.
0 to 10000 2000
ms
O
210
78
C4: Torque Compensation
Use C4 parameters to configure Torque Compensation function.
C4-01
<22>
Torque
Compensation
Gain
Sets the gain for the automatic torque (voltage) boost function and
helps to produce better starting torque.
Increase this setting when using a long motor cable or when the
motor is significantly smaller than the drive capacity.
Decrease this setting when motor oscillation occurs. Set the value
so that the current at low speed does not exceeds the drive rated
current.
0.00 to
2.50
1.00
O
215
78
C6: Carrier Frequency
Use C6 parameters to configure the carrier frequency drive settings.
C6-01
Normal/Heavy
Duty Selection
Selects the load rating for the drive.
0: Heavy Duty (HD) for constant torque applications.
1: Normal Duty (ND) for variable torque applications.
This setting affects the Rated output current and overload tolerance
of the drive.
0, 1
0
S
223
79
B.2 Parameter Table
172
SIEP C710606 33A OYMC AC Drive – J1000 User Manual
Содержание JZA
Страница 2: ......
Страница 24: ...1 3 Component Names This Page Intentionally Blank 22 SIEP C710606 33A OYMC AC Drive J1000 User Manual...
Страница 52: ...3 12 Wiring Checklist This Page Intentionally Blank 50 SIEP C710606 33A OYMC AC Drive J1000 User Manual...
Страница 70: ...4 9 Test Run Checklist This Page Intentionally Blank 68 SIEP C710606 33A OYMC AC Drive J1000 User Manual...
Страница 162: ...8 5 Communication Options This Page Intentionally Blank 160 SIEP C710606 33A OYMC AC Drive J1000 User Manual...
Страница 210: ...C 13 Self Diagnostics This Page Intentionally Blank 208 SIEP C710606 33A OYMC AC Drive J1000 User Manual...
Страница 230: ...Index This Page Intentionally Blank 228 SIEP C710606 33A OYMC AC Drive J1000 User Manual...
Страница 231: ...This Page Intentionally Blank SIEP C710606 33A OYMC AC Drive J1000 User Manual 229...