A.2 Single/Three-Phase 200 V Class Drive
Table A.2 Power Ratings
Item
Specification
Three-Phase: JZA
20P1
20P2
20P4
20P7
21P5
22P2
24P0
Single-Phase: JZA
<1>
B0P1
B0P2
B0P4
B0P7
B1P5
-
-
Maximum Motor Size Allowed (kW)
<2>
HD Rating
0.1
0.2
0.4
0.75
1.5
2.2
4.0
ND Rating
0.2
0.4
0.75
1.1
2.2
3.0
5.5
Input
Input Current (A)
<3>
Three-Phase
HD Rating
0.7
1.5
2.9
5.8
7.5
11.0
18.9
ND Rating
1.1
1.9
3.9
7.3
10.8
13.9
24.0
Single-Phase
HD Rating
1.4
2.8
5.5
11.0
14.1
-
-
ND Rating
2.0
3.6
7.3
13.8
20.2
-
-
Output
Rated Output Capacity (kVA)
<4>
HD Rating
0.3
0.6
1.1
1.9
3.0
4.2
6.7
ND Rating
0.5
0.7
1.3
2.3
3.7
4.6
7.5
Output Current (A)
HD Rating
0.8
<6>
1.6
<6>
3.0
<6>
5.0
<6>
8.0
<7>
11.0
<7>
17.5
<7>
ND Rating
<5>
1.2
1.9
3.5(3.3)
6.0
9.6
12.0
19.6
Overload Tolerance
ND Rating: 120% of rated output current for 1 minute
HD Rating: 150% of rated output current for 1 minute
(Derating may be required for applications that start and stop frequently)
Carrier Frequency
2 kHz (user-set, 2 to 15 kHz)
Max Output Voltage (V)
Three-phase 200 to 240 V (proportional to input voltage)
Max Output Frequency (Hz)
400 Hz (user-adjustable)
Power
Supply
Rated Voltage
Rated Frequency
Three-phase power: Three-phase 200 to 240 V 50/60 Hz
Single-phase power: 200 to 240 V 50/60 Hz
Allowable Voltage Fluctuation
-15 to 10%
Allowable Frequency Fluctuation
±5%
Harmonic Corrective Actions
DC Reactor
Optional
<1> Drives with a single-phase power supply input output three-phase power, and cannot run a single-phase motor.
<2> The motor capacity (kW) refers to a Yaskawa 4-pole motor. The rated output current of the drive output amps should be equal to or greater
than the motor rated current.
<3> Input current rating varies depending on the power supply transformer, input reactor, wiring connections, and power supply impedance.
<4> Rated motor capacity is calculated with a rated output voltage of 220 V.
<5> Carrier frequency is set to Swing PWM. Current derating is required in order to raise the carrier frequency.
<6> Carrier frequency is set to 10 kHz. Current derating is required in order to raise the carrier frequency.
<7> Carrier frequency is set to 8 kHz. Current derating is required in order to raise the carrier frequency.
Note:
Differences between Heavy Duty (HD) ratings and Normal Duty (ND) ratings for the drive include rated input and output current, overload
capacity, carrier frequency and current limit. Set parameter C6-01 to “0” (default) for HD or “1” for ND.
A.2 Single/Three-Phase 200 V Class Drive
SIEP C710606 33A OYMC AC Drive – J1000 User Manual
163
A
Specifications
Содержание JZA
Страница 2: ......
Страница 24: ...1 3 Component Names This Page Intentionally Blank 22 SIEP C710606 33A OYMC AC Drive J1000 User Manual...
Страница 52: ...3 12 Wiring Checklist This Page Intentionally Blank 50 SIEP C710606 33A OYMC AC Drive J1000 User Manual...
Страница 70: ...4 9 Test Run Checklist This Page Intentionally Blank 68 SIEP C710606 33A OYMC AC Drive J1000 User Manual...
Страница 162: ...8 5 Communication Options This Page Intentionally Blank 160 SIEP C710606 33A OYMC AC Drive J1000 User Manual...
Страница 210: ...C 13 Self Diagnostics This Page Intentionally Blank 208 SIEP C710606 33A OYMC AC Drive J1000 User Manual...
Страница 230: ...Index This Page Intentionally Blank 228 SIEP C710606 33A OYMC AC Drive J1000 User Manual...
Страница 231: ...This Page Intentionally Blank SIEP C710606 33A OYMC AC Drive J1000 User Manual 229...