7
M
eth
od
s
fo
rC
on
ne
ctin
g
an
d
C
om
m
un
ica
tin
g
w
ith
E
xte
rn
al
D
ev
ice
s
FZ4 User's Manual
Controlling/Outputting through Parallel Communication
543
Important
●
That status of each of the parallel terminal signals STEP, DSA, GATE, OR, and READY can be checked
on the screen with STEP0, DSA0, GATE0, OR0, and READY0.
●
If the operation mode (FZ4-11
/H11
only) is [Multi-line random-trigger mode], line 0 uses
GATE0, OR0, READY0, STEP0 and DSA0, while line 1 uses GATE1, OR1, READY1, STEP1 and
DSA1.
●
If the operation mode (FZ4-11
/H11
only) is [Multi-line random-trigger mode], the RUN signal
cannot be checked.
●
If the operation mode (FZ4-11
/H11
only) is [Multi-line random-trigger mode], the ERR signal
is used in common.
3.
Change the contents to be sent.
When switching between "ON"/"OFF" is performed, the changed contents are displayed on the
monitors of external devices. Please verify it.
4.
Tap [OK].
The Parallel window closes.
I/O Format (Parallel Interface)
Input Format
When the Main screen is displayed, the following commands can be input.
●
STEP signal
Measurement is performed once when STEP signal turns on.
●
DSA signal
When "Output Control" is set to "Handshaking", this is a signal to provide notification that the
external device is ready to receive data.
Reference:
Setting Communication Specifications (Parallel Interface) (p.540)
●
DI signal
Commands can be input in the following format. Set 0 (OFF) or 1 (ON) for each DI signal.
Confirm commands and information, and turn DI7 (execute) ON with an interval of at least 1 ms.
Acesst 1.0 6251194
Содержание FZ4 Series
Страница 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Страница 12: ...1 Before Operation 10 Operation Flow FZ4 User s Manual Operation Flow Here describes the operation flow...
Страница 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Страница 112: ...3 Performing Test Measurement Starting Operation 110 Useful Functions for Operation FZ4 User s Manual...
Страница 326: ...4 Using Tool 324 Remotely Operating the Controller Remote Operation FZ4 User s Manual Enter the IP address...
Страница 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Страница 351: ...6 Changing the System Environment FZ4 User s Manual Setting the System Operation Environment 349 Communication...
Страница 566: ......
Страница 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Страница 654: ...652 FZ4 User s Manual...
Страница 655: ......