7
M
eth
od
s
fo
rC
on
ne
ctin
g
an
d
C
om
m
un
ica
tin
g
w
ith
E
xte
rn
al
D
ev
ice
s
530
Control/Output through EtherNet/IP
FZ4 User's Manual
・
Assignment Example for Variable Data Type That Matches the Response and Output
Areas
2.
Defining the Variables
Define variables for the data links for the communications area data that is used in EtherNet/IP
communications.
These variables use the data types that were defined above in procedure 1.
Variable
Variable type
Network
Publish
attribute
Data type
Application
EIPOutput
Global variable
Output
S_EIPOutput For data links to the command area
EIPInput
Global variable
Input
S_EIPInput
For data links to the response and
output areas
3.
Exporting the Variables That Were Defined on Sysmac Studio
Export the variables that you defined so that you can use them on the Network Configurator.
An exported CSV file is created.
4.
Network Configurator Settings
1.
Import to the Network Configurator the CSV file that you exported from the Sysmac
Studio.
The variables that are imported will automatically be registered as tags.
2.
Set the connections as shown in the following table.
Originator device (PLC) settings
Target device (Sensor) settings
Input tag set: EIPOutput
Output tag set: Input101
Output tag set: EIPInput
Input tag set: Output100
5.
Accessing the Communications Areas from the User Program
The defined variables are used to access the communications areas for the Sensor using the
following notation.
Acesst 1.0 6251194
Содержание FZ4 Series
Страница 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Страница 12: ...1 Before Operation 10 Operation Flow FZ4 User s Manual Operation Flow Here describes the operation flow...
Страница 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Страница 112: ...3 Performing Test Measurement Starting Operation 110 Useful Functions for Operation FZ4 User s Manual...
Страница 326: ...4 Using Tool 324 Remotely Operating the Controller Remote Operation FZ4 User s Manual Enter the IP address...
Страница 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Страница 351: ...6 Changing the System Environment FZ4 User s Manual Setting the System Operation Environment 349 Communication...
Страница 566: ......
Страница 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Страница 654: ...652 FZ4 User s Manual...
Страница 655: ......