6
Changing
the
System
Environment
FZ4 User's Manual
Setting the System Operation Environment
355
Enable
timing
●
[ENABLE
start]
●
STEP start
Sets the timing for starting the pulse count.
ENABLE start: Counts the pulses input during the
measurement trigger receipt period.
STEP start: Does not count pulses even during the
measurement trigger receipt period until the STEP
signal is input.
Pulse reset
timing
●
[Every trigger
pulse]
Sets the timing for resetting.
Pulse Z
[0] to 1023
Sets how many pulses it takes for the trigger to be
produced.
Important
●
The encoder trigger setting is disabled in the FZ4-L35
series.
Setting the STEP Input Detection Pulse Width [STEP Setting]
This setting is performed as a countermeasure against STEP input chattering and to prevent operation
malfunctions due to entrance of noise.
When Filter Setting Value Is 100 μs (Initial Value)
The STEP signal is detected as being on at the point it is on continuously for at least 100 μs, and
measurement begins at this point.Accordingly, STEP signal detection is delayed by an amount of time
equivalent to the set filter value. Also, when turning from ON to OFF, the OFF filter fixed at 500 μs is
activated and the STEP signal is detected as OFF when it is off for at least 500 μs.
1.
On the Main screen, tap the [System] menu - [Controller] - [STEP setting].
2.
Set the filter width in the "STEP setting" area.
Acesst 1.0 6251194
Содержание FZ4 Series
Страница 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Страница 12: ...1 Before Operation 10 Operation Flow FZ4 User s Manual Operation Flow Here describes the operation flow...
Страница 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Страница 112: ...3 Performing Test Measurement Starting Operation 110 Useful Functions for Operation FZ4 User s Manual...
Страница 326: ...4 Using Tool 324 Remotely Operating the Controller Remote Operation FZ4 User s Manual Enter the IP address...
Страница 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Страница 351: ...6 Changing the System Environment FZ4 User s Manual Setting the System Operation Environment 349 Communication...
Страница 566: ......
Страница 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Страница 654: ...652 FZ4 User s Manual...
Страница 655: ......