4
Using
Tool
FZ4 User's Manual
Using NG Analyser
117
In the above example, [Search] becomes the adjustment target.
7.
The cause of NG is displayed. To check the details of values further, tap [Details of data].
8.
Adjust the processing item by referring to the displayed content.
In the following example, Correlation values are clearly lower on some screens.
Based on the revealed cause of false judgement, use the [Set up(Std.)] and [Set up(Select)]
buttons to change the setting values of the processing unit.