344
Setting Conditions Related to Operation during Measurement
FZ4 User's Manual
Setting Conditions Related to Operation
during Measurement
With operation during measurement, the following items can be changed.
●
Operation when the next STEP signal is input during measurement
●
Saving of scene groups during scene group switching
1.
On the Main screen, tap the [Measure] menu - [Measure setting].
The Measurement Setting window is displayed.
2.
Set each item as required.
When they are not displayed, create settings through the [System] menu - [Controller] - [Create
shortcut].
Item
Set value
[Factory default]
Description
STEP in
measure
●
[ERROR ON]
●
ERROR OFF
Sets whether the ERROR signal output turns on when the
following STEP signals are input during measurement.
Save scene
group on
scene switch
●
[Checked]
●
Unchecked
Sets operation when scene group switching is performed.Sets
whether the scene group is saved when it is switched.The scene
group switching time can be reduced if the check is removed,
but if the power is turned off without saving when settings have
been changed, the changed contents will be cleared.
Scene
switch time
Add time
[ms]
0 to 1000
[10]
The BUSY signal is turned on during scene switching.When this
time is short and the change from ON to OFF cannot be
detected by external devices, the BUSY signal ON time can be
added.This is set in 1 ms units.The displayed value can be
changed in 5 ms increments by tapping "<" and ">".
Note
●
The settings of "Save scene group on scene switch" are linked with the settings of the Switch Scene
Group window.Settings specified later override the previous ones.
Reference:
Switching Scenes and Scene Groups (p.65)
3.
Tap [OK].
The display returns to the Main screen.
Acesst 1.0 6251194
Содержание FZ4 Series
Страница 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Страница 12: ...1 Before Operation 10 Operation Flow FZ4 User s Manual Operation Flow Here describes the operation flow...
Страница 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Страница 112: ...3 Performing Test Measurement Starting Operation 110 Useful Functions for Operation FZ4 User s Manual...
Страница 326: ...4 Using Tool 324 Remotely Operating the Controller Remote Operation FZ4 User s Manual Enter the IP address...
Страница 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Страница 351: ...6 Changing the System Environment FZ4 User s Manual Setting the System Operation Environment 349 Communication...
Страница 566: ......
Страница 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Страница 654: ...652 FZ4 User s Manual...
Страница 655: ......