7
M
eth
od
s
fo
rC
on
ne
ctin
g
an
d
C
om
m
un
ica
tin
g
w
ith
E
xte
rn
al
D
ev
ice
s
FZ4 User's Manual
Communicating through Serial Communication (PLC Link)
409
Command (PLC to controller)
Command
area
top channel
Command
code
Bit
Description
15-12
11-8
7-4
3-0
+2
A000
1010
0000
0000
0000
Sets command codes.
+3
0030
0000
0000
0011
0000
+4
―
0000
0000
0000
0000
Specifies the operation log
state.
ON: 1
OFF: 0
+5
―
0000
0000
0000
0000
Response (Controller to PLC)
Response
area
top channel
Bit
Description
15-12
11-8
7-4
3-0
+2
1010
0000
0000
0000
Command code
Store response target command codes.
+3
0000
0000
0011
0000
+4
0000
0000
0000
0000
Response code
Command execution result
OK: 0 (0000 0000)
NG: -1 (FFFF FFFF)
+5
0000
0000
0000
0000
Acquiring Unit Data
Acquires the specified processing unit data.
Important
●
In unit data setting/acquisition, external reference table No. 139 (verification string) of Character Inspection,
external reference table No. 164 (judgement comparison character string) of b, and external reference
table No. 172 (judgement comparison character string) of 2D Code and 2D Code+ cannot be used.
Command (PLC to controller)
Command
area
top channel
Command
code
Bit
Description
15-12
11-8
7-4
3-0
+2
1000
0001
0000
0000
0000
Set command codes.
+3
0040
0000
0000
0100
0000
+4
-
0000
0000
0000
0000
Specifies the unit No.
+5
-
0000
0000
0000
0000
+6
-
0000
0000
0000
0000
Specifies data number in
the External Reference
Tables.
+7
-
0000
0000
0000
0000
Acesst 1.0 6251194
Содержание FZ4 Series
Страница 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Страница 12: ...1 Before Operation 10 Operation Flow FZ4 User s Manual Operation Flow Here describes the operation flow...
Страница 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Страница 112: ...3 Performing Test Measurement Starting Operation 110 Useful Functions for Operation FZ4 User s Manual...
Страница 326: ...4 Using Tool 324 Remotely Operating the Controller Remote Operation FZ4 User s Manual Enter the IP address...
Страница 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Страница 351: ...6 Changing the System Environment FZ4 User s Manual Setting the System Operation Environment 349 Communication...
Страница 566: ......
Страница 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Страница 654: ...652 FZ4 User s Manual...
Страница 655: ......