Setting Operation Mode
FZ4 User's Manual
The screen returns to the RUN window.
Important
●
When [Transfer data] is executed, the results of [Trend Monitor] and [Expression], etc. are cleared.
●
If the scene or scene group was switched or any setting of a processing unit was changed during operation
using an external command, the result is not yet reflected when you switch to the non-stop adjustment window.
●
If non-stop adjustment is performed after changing the scene group during operation, scene group data may be
overwritten against your wish.
●
Measurement commands (parallel, non-procedure, PLC link) and continuous measurement commands (parallel
only) are the only communication commands that are accepted during data transfer.
●
Data transfer takes a longer time when the scene group file size is larger.
●
If the RUN window is displayed in the fast view mode, non-stop adjustment cannot be performed.
●
Communication settings cannot be changed on the non-stop adjustment window.
●
Do not register any new camera image input unit on the non-stop adjustment window.
●
If RAMDisk does not have enough free disk capacity, data may not be transferred. Specify an image logging
destination other than RAMDisk or otherwise set applicable items to minimize the usage of RAMDisk.
●
Performing non-stop adjustment changes the display mode to freeze.
●
If image logging is performed in the non-stop adjustment mode, data transfer may be disabled. To prevent this
from happening, set the trigger interval longer than the logging time.
Acesst 1.0 6251194
Содержание FZ4 Series
Страница 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Страница 12: ...1 Before Operation 10 Operation Flow FZ4 User s Manual Operation Flow Here describes the operation flow...
Страница 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Страница 112: ...3 Performing Test Measurement Starting Operation 110 Useful Functions for Operation FZ4 User s Manual...
Страница 326: ...4 Using Tool 324 Remotely Operating the Controller Remote Operation FZ4 User s Manual Enter the IP address...
Страница 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Страница 351: ...6 Changing the System Environment FZ4 User s Manual Setting the System Operation Environment 349 Communication...
Страница 566: ......
Страница 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Страница 654: ...652 FZ4 User s Manual...
Страница 655: ......