FZ4 User's Manual
Controlling/Outputting through Parallel Communication
541
Item
Setting
value
[Factory
default]
Description
Output polarity
●
[On at
NG]
●
On at
OK
Select whether to turn on OR and DO0 to 15 when
judgement result is OK or when it is NG.
Output control
[None]
Method to output measurement results without synchronizing
with external devices.
Reference:
When "Output Control" Is Set to "None" (p.547)
Handshaking
Method to output measurement results while synchronizing with
external devices.
Reference:
When "Output Control" Is Set to "Handshaking" (p.551)
Synchronization
output
Method to output measurement results while
synchronizing with line processing timing. The STEP
signal is ignored the number of times set in "Number of
delay", and measurement results are output when the
STEP signal next turns on. If through images are
displayed, however, synchronization output cannot be
used.
Reference:
When "Output Control" Is Set to
"Synchronization Output" (p.552)
Output period
2.0 to
5000.0 ms
[10.0 ms]
Valid only when "Output control" is set to "None".
Set the cycle by which measurement results are output.
Set the cycle so that the interval is equal to or longer
than "Gate ON delay + Output time" and shorter than
measurement interval.
If the cycle is longer than the measurement interval,
output timing will be delayed while measurement is
being repeated.
Gate ON delay
1.0 to
1000.0 ms
[1.0 ms]
Set the time from when results are output to the parallel
interface to when the GATE signal turns on. Waiting
time until data output is stable.
Set this so that it is longer than the external device
delay time.
Output time
1.0 to
1000.0 ms
[5.0 ms]
Valid only when "Output control" is set to "None" or
"Synchronization output".
Set the GATE signal ON time. Set the time required for
external devices to acquire measurement results.
Timeout
0.5 to 120.0
s
[10.0 s]
Valid only when "Output control" is set to
"Handshaking".
A timeout error occurs when no response from external
devices is received within the time that has been set.
Number of delay
1 to 15
[1]
Valid only when "Output control" is set to
"Synchronization output".
Set the number of times that the STEP signal turning
on will be ignored before measurement results of the
STEP signal are output.
One-shot OR signal
●
ON
●
[OFF]
Select whether to maintain OR signal output for an
arbitrary amount of time.
Output time
0.1 to
1000.0 ms
[5.0 ms]
Set the OR signal output time.
Valid only when "One-shot OR signal" is set to ON. Set
a value that is shorter than the measurement time.
Acesst 1.0 6251194
Содержание FZ4 Series
Страница 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Страница 12: ...1 Before Operation 10 Operation Flow FZ4 User s Manual Operation Flow Here describes the operation flow...
Страница 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Страница 112: ...3 Performing Test Measurement Starting Operation 110 Useful Functions for Operation FZ4 User s Manual...
Страница 326: ...4 Using Tool 324 Remotely Operating the Controller Remote Operation FZ4 User s Manual Enter the IP address...
Страница 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Страница 351: ...6 Changing the System Environment FZ4 User s Manual Setting the System Operation Environment 349 Communication...
Страница 566: ......
Страница 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Страница 654: ...652 FZ4 User s Manual...
Страница 655: ......