6
Changing
the
System
Environment
358
Setting the System Operation Environment
FZ4 User's Manual
Important
●
When image logging or data logging is executed for a network drive, the communication may be disrupted and
the logging process may not be executed successfully due to the controller measurement load that becomes too
heavy when the multiple image input function is used. In this case, set a reasonable amount of measurement
takt time.
●
If many drives are set as network drives, it may require a greater amount of time to start the controller.
●
Do not pull out the LAN cable while the controller is accessing the network drives.
●
Start the controller when the network drives are ready. A connection cannot be established if the network drives
are not ready when the controller is started.
●
If there is no access to a network drive for a certain amount of time, the connection will be automatically cut off
depending on the network drive setting of the connection target. Make sure that the setting on the connection
target is not set to automatic disconnection.
●
Date and time of the update of the file created at network logging
If the time zone of the external device is different from the time zone setting of the controller [GMT-08:00 Pacific
Time (US & Canada): Do not automatically adjust clock for Daylight Saving Time], the date and time actually
written may be different from the date and time of the file update. Adjust the time zone of the external device to
match that of the controller's.
Checking System Information [System Information]
The controller model and measurement application version can be checked.
You can check the USB memory status with FZ4-11
/H11
series only.
1.
On the Main screen, tap [Other] menu - [System information].
The System Information window is displayed.
2.
Check the information.
The controller model and measurement application version can be checked.
3.
Tap [Memory state].
The following information can be checked.
●
Available application memory
The application memory is the memory used by all applications.
By confirming available memory, this provides a rough standard for confirming status
while operating.
●
Available data memory (FZ4-L35
/ FZ4-6
/FZ4-H6
/FZ4-7
/FZ4-H7
only)
The data memory is the amount of memory that can be used for scene group data. Check
the available memory that can be used for unit data and settings data for each unit.
4.
Tap [Close].
The System Information window closes.
Acesst 1.0 6251194
Содержание FZ4 Series
Страница 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Страница 12: ...1 Before Operation 10 Operation Flow FZ4 User s Manual Operation Flow Here describes the operation flow...
Страница 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Страница 112: ...3 Performing Test Measurement Starting Operation 110 Useful Functions for Operation FZ4 User s Manual...
Страница 326: ...4 Using Tool 324 Remotely Operating the Controller Remote Operation FZ4 User s Manual Enter the IP address...
Страница 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Страница 351: ...6 Changing the System Environment FZ4 User s Manual Setting the System Operation Environment 349 Communication...
Страница 566: ......
Страница 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Страница 654: ...652 FZ4 User s Manual...
Страница 655: ......