368
Communicating through Serial Communication (PLC Link)
FZ4 User's Manual
Address
0 to 99999
[0]
Set the top channel address in the
Command area.
Response area
Area
●
[Data register]
●
File register
●
Link register
Set the Response area.
Address
0 to 99999
[100]
Set the top channel address in the
Response area.
Data output area
Area
●
[Data register]
●
File register
●
Link register
Set the Data output area.
Address
0 to 99999
[200]
Set the top channel address in the Data
output area.
Output control
●
None
●
[Handshaking]
Set whether or not to provide an interlock
with the PLC when performing data output.
None: Data is output regardless of the status
of signals from the PLC. GATE is always
OFF.
Handshaking: Data is output after confirming
DSA from the PLC.
Retry interval [ms]
1000 to 999999
[10000]
Set the communication retry interval.
5.
Tap [OK].
The settings are confirmed and the Ethernet window closes.
Checking Communication Status
Use PLC tools, etc. to check the communication status.
Important
●
The communication time is different depending on the communication environment. Make sure to verify on the
actual usage environment before use. The communication speed of the controllers for the FZ4-L35
/6
/7
series may be faster than the speed of the controllers for FZ4-11
series depending on the conditions.
Setting Communication Specifications (RS-232C/422-PLC Link)
Communication specifications such as link areas or communication speed and data length are set.
Reference:
Setting Communication Specifications (Ethernet - PLC Link) (p.363)
Important
●
Before setting the communication specifications, set the "Serial (RS-232C/422)" communication module to
"PLC link (SYSMAC CS/CJ/CP/One)" (or to "PLC link (MELSEC Q series)" in the case of a PLC by Mitsubishi
Electric Corporation), save the setting to the controller, and then restart the system. When the system is
restarted, the communication settings are initialized.
Reference:
Setting the Start-up Status [Startup Setting] (p.347)
●
Use the same communication specification settings for the controller and the external device.
●
If the operation mode (FZ4-11
/H11
only) is [Multi-line random-trigger mode], "RS232C/422-PLC link"
cannot be selected for line 1.
1.
On the Main screen, tap the [System] menu - [Communication] - [RS-232C/RS-422:PLC Link].
The serial interface window is displayed.
Acesst 1.0 6251194
Содержание FZ4 Series
Страница 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Страница 12: ...1 Before Operation 10 Operation Flow FZ4 User s Manual Operation Flow Here describes the operation flow...
Страница 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Страница 112: ...3 Performing Test Measurement Starting Operation 110 Useful Functions for Operation FZ4 User s Manual...
Страница 326: ...4 Using Tool 324 Remotely Operating the Controller Remote Operation FZ4 User s Manual Enter the IP address...
Страница 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Страница 351: ...6 Changing the System Environment FZ4 User s Manual Setting the System Operation Environment 349 Communication...
Страница 566: ......
Страница 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Страница 654: ...652 FZ4 User s Manual...
Страница 655: ......