40
Specifications
Section 2-2
Note
(1) The above values are for a cold start at room temperature for an AC pow-
er supply, and for a cold start for a DC power supply.
• A thermistor (with low-temperature current suppression characteris-
tics) is used in the inrush current control circuitry for the AC power sup-
ply. The thermistor will not be sufficiently cooled if the ambient
temperature is high or if a hot start is performed when the power sup-
ply has been OFF for only a short time, so in those cases the inrush
current values may be higher (as much as two times higher) than those
shown above.
• A capacitor delay circuit is used in the inrush current control circuitry
for the DC power supply. The capacitor will not be charged if a hot start
is performed when the power supply has been OFF for only a short
time, so in those cases the inrush current values may be higher (as
much as two times higher) than those shown above.
Always allow for this when selecting fuses and breakers for external cir-
cuits.
(2) Use the external power supply to power input devices. Do not use it to
drive output devices.
(3) This is the rated value for the maximum system configuration. Use the fol-
lowing formula to calculate DC power consumption for CPU Units with DC
power.
External power supply (See note 2.)
300 mA at 24 VDC (CP1L-M
@
DR-A)
200 mA at 24 VDC (CP1L-L
@
DR-A)
None
Insulation resistance
20 M
Ω
min. (at 500 VDC) between the
external AC terminals and GR terminals
No insulation between primary and sec-
ondary DC power supplies.
Dielectric strength
2,300 VAC 50/60 Hz for 1 min between
the external AC and GR terminals, leak-
age current: 5 mA max.
No insulation between primary and sec-
ondary DC power supplies.
Noise resistance
Conforms to IEC 61000-4-4 2 kV (power supply line)
Vibration resistance
10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, acceleration: 9.8 m/s
2
in X, Y, and
Z directions for 80 minutes each (time coefficient of 8 minutes
×
coefficient factor
of 10 = total time of 80 minutes)
Shock resistance
147 m/s
2
three times each in X, Y, and Z directions
Ambient operating temperature
0 to 55
°
C
Ambient humidity
10% to 90% (with no condensation)
Atmosphere
No corrosive gas.
Ambient storage temperature
−
20 to 75
°
C (excluding battery)
Terminal screw size
M3
Power interrupt time
10 ms min.
2 ms min.
Weight
CP1L-M40D
@
-
@
: 675 g max.
CP1L-M30D
@
-
@
: 610 g max.
CP1L-L20D
@
-
@
: 380 g max.
CP1L-L14D
@
-
@
: 380 g max.
CP1L-J20D
@
-
@
: 380 g max.
CP1L-J14D
@
-
@
: 380 g max.
Power supply classification
AC power supply
DC power supply
Model
numbers
40 I/O points
CP1L-M40DR-A
CP1L-M40DR-D, CP1L-M40DT-D, or
CP1L-M40DT1-D
30 I/O points
CP1L-M30DR-A
CP1L-M30DR-D, CP1L-M30DT-D, or
CP1L-M30DT1-D
20 I/O points
CP1L-L20DR-A
CP1L-J20DR-A
CP1L-L20DR-D, CP1L-L20DT-D,
CP1L-L20DT1-D, CP1L-J20DR-D, or
CP1L-J20DT1-D
14 I/O points
CP1L-L14DR-A
CP1L-J14DR-A
CP1L-L14DR-D, CP1L-L14DT-D,
CP1L-L14DT1-D, CP1L-J14DR-D, or
CP1L-J14DT1-D
Содержание CP1L - 12-2007
Страница 3: ...iv...
Страница 9: ...x...
Страница 13: ...xiv TABLE OF CONTENTS...
Страница 21: ...xxii...
Страница 33: ...xxxiv Conformance to EC Directives 6...
Страница 65: ...32 Function Blocks Section 1 5...
Страница 428: ...395 Clock Section 6 9...
Страница 429: ...396 Clock Section 6 9...
Страница 523: ...488 Troubleshooting Unit Errors Section 9 4...
Страница 531: ...496 Replacing User serviceable Parts Section 10 2...
Страница 563: ...528 Auxiliary Area Allocations by Function Appendix C...
Страница 611: ...576 Auxiliary Area Allocations by Address Appendix D...
Страница 638: ...603 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Страница 639: ...604 Connections to Serial Communications Option Boards Appendix F...
Страница 669: ...634 Index...
Страница 671: ...636 Revision History...