530
Auxiliary Area Allocations by Address
Appendix D
A22
---
Error Counter
0 Present
Value, Signed
This word contains the present value
of the error counter for inverter posi-
tioning 0.
Data range: 8000 to 7FFF hex
(
−
32,768 to 32,767) (signed)
---
---
Cleared
Every error
counter 0
cycle
---
A23
---
Inverter Fre-
quency 0
Command
Value
This word contains the automatically
calculated frequency command
value for the inverter for inverter posi-
tioning 0.
Data range: 0000 to FFFF hex (0.00
to 655.35 Hz) (0.01-Hz increments,
unsigned)
Set the Power Supply Frequency for
One Motor Revolution per Second,
Number of Encoder Pulses for One
Motor Revolution, and Error Counter
Cycle for inverter positioning 0 in the
PLC Setup before using this value.
---
---
Cleared
Every error
counter 0
cycle
---
A24
and
A25
---
Present Value
of Signed Out-
put Value 0
These words contain the present
value of the signed output value (out-
put value = present value of error
counter
×
error counter cycle (s)
×
gain) for inverter positioning 0.
Data range: 8000 0000 to 7FFF
FFFF hex (
−
214,748,348 to
214,748,347) (signed)
The maximum and minimum output
values set for inverter positioning 0 in
the PLC Setup are applied.
A25 contains the leftmost 4 digits
and A24 contains the rightmost 4
digits.
---
---
Cleared
Every error
counter 0
cycle
---
A26
00
Operation
Command
Flag 0
This flag turns ON during an opera-
tion command for inverter positioning
0.
ON: Opera-
tion command
executed.
OFF: Stop
command
executed.
---
Cleared
When
inverter
positioning
0 is started
---
01
Forward Oper-
ation Com-
mand Flag 0
This flag turns ON during a forward
operation command for inverter posi-
tioning 0.
ON: Forward
command in
progress
OFF: Reverse
command in
progress or
stopped
---
Cleared
When
present
value of
error
counter 0
is positive
---
02
Reverse Oper-
ation Com-
mand Flag 0
This flag turns ON during a reverse
operation command for inverter posi-
tioning 0.
ON: Reverse
command in
progress
OFF: For-
ward com-
mand in
progress or
stopped
---
Cleared
When
present
value of
error
counter 0
is negative
---
03
In-position
Flag 0
This flag turns ON when inverter
positioning 0 is in position.
ON: In posi-
tion
OFF: Not in
position
---
Cleared
When
pulse out-
put to error
counter 0
is stopped
and the
present
value of
error
counter 0
is within
the in-posi-
tion range
---
Address
Name
Function
Settings
Status
after
mode
change
Status
at star-
tup
Write
timing
Related
flags, set-
tings
Words
Bits
Содержание CP1L - 12-2007
Страница 3: ...iv...
Страница 9: ...x...
Страница 13: ...xiv TABLE OF CONTENTS...
Страница 21: ...xxii...
Страница 33: ...xxxiv Conformance to EC Directives 6...
Страница 65: ...32 Function Blocks Section 1 5...
Страница 428: ...395 Clock Section 6 9...
Страница 429: ...396 Clock Section 6 9...
Страница 523: ...488 Troubleshooting Unit Errors Section 9 4...
Страница 531: ...496 Replacing User serviceable Parts Section 10 2...
Страница 563: ...528 Auxiliary Area Allocations by Function Appendix C...
Страница 611: ...576 Auxiliary Area Allocations by Address Appendix D...
Страница 638: ...603 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Страница 639: ...604 Connections to Serial Communications Option Boards Appendix F...
Страница 669: ...634 Index...
Страница 671: ...636 Revision History...