2-20
2-2 Wiring
2
De
sign
*1. When the cable is connected without using the crimp terminal (bare wires), use the square washer included
with the product.
Note: The cable size is based on the HIV cable (75
°
C heat resistance).
40
0-V cl
ass
0.4
3G3RX-
A4004
1.25
1.25
1.25
M4
1.25-4
1.2
(max.1.8)
5 A
0.75
3G3RX-
A4007
1.25
1.25
1.25
M4
1.25-4
1.2
(max.1.8)
5 A
1.5
3G3RX-
A4015
2
2
2
M4
2-4
1.2
(max.1.8)
10 A
2.2
3G3RX-
A4022
2
2
2
M4
2-4
1.2
(max.1.8)
10 A
3.7
3G3RX-
A4037
2
2
2
M4
2-4
1.2
(max.1.8)
15 A
5.5
3G3RX-
A4055
3.5
3.5
3.5
M5
R2-5
2.4
(max. 4.0)
30 A
7.5
3G3RX-
A4075
3.5
3.5
3.5
M5
3.5-5
2.4
(max. 4.0)
30 A
11
3G3RX-
A4110
5.5
5.5
5.5
M6
R5.5-6
4.5
(max. 4.4)
50 A
15
3G3RX-
A4150
8
8
8
M6
8-6
4.5
(max. 4.9)
60 A
18.5
3G3RX-
A4185
14
14
14
M6
14-6
4.5
(max. 4.9)
60 A
22
3G3RX-
A4220
14
14
14
M6
14-6
4.5
(max. 4.9)
75 A
30
3G3RX-
A4300
22
22
-
M6
22-6
4.5
(max. 4.9)
100 A
37
3G3RX-
A4370
38
22
⎯
M8
*1
38-8
8.1
(max. 20.0)
100 A
45
3G3RX-
A4450
38
22
⎯
M8
*1
38-8
8.1
(max. 20.0)
150 A
55
3G3RX-
A4550
60
30
⎯
M8
*1
R60-8
8.1
(max. 20.0)
175 A
75
3G3RX-
A4750
100
(38
×
2)
38
⎯
M10
*1
100-10
20.0
(max. 22.0)
225 A
90
3G3RX-
A4900
100
(38
×
2)
38
⎯
M10
*1
100-10
20.0
(max. 22.0)
225 A
110
3G3RX-
A411K
150
(60
×
2)
60
⎯
M10
*1
150-10
20.0
(max. 35.0)
350 A
132
3G3RX-
A413K
80
×
2
80
⎯
M10
*1
80-10
20.0
(max. 35.0)
350 A
Motor
output
(kW)
Applicable
Inverter
model
Power cable
(mm
2
)
R, S, T, U, V,
W, +1, P/+2,
N/-
Ground
cable
(mm
2
)
External
braking resistor
b1
and RB (mm
2
)
Terminal
screw
size
Crimp
terminal
Tightening
torque
N•m
Applicable
device
Earth leakage
breaker (ELB)
Содержание 3G3RX Series
Страница 1: ...Cat No I560 E1 03 USER S MANUAL SYSDRIVE RXSERIES High function General purpose Inverter ...
Страница 2: ......
Страница 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 4 ...
Страница 22: ......
Страница 23: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Wiring 2 6 ...
Страница 48: ......
Страница 108: ......
Страница 324: ......
Страница 325: ...Chapter 5 Maintenance Operations 5 1 Protective Functions and Troubleshooting 5 1 5 2 Warning Function 5 10 ...
Страница 337: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 ...
Страница 348: ......
Страница 349: ...Chapter 7 Specifications 7 1 Standard Specification List 7 1 7 2 Dimensional Drawing 7 6 7 3 Options 7 14 ...
Страница 358: ...7 9 7 2 Dimensional Drawing 7 Specifications 3G3RX A2300 A4300 368 79 265 310 10 510 540 2 φ10 195 45 80 265 ...
Страница 360: ...7 11 7 2 Dimensional Drawing 7 Specifications 3G3RX A2550 380 670 700 2 φ12 12 380 480 250 352 79 ...
Страница 361: ...7 12 7 2 Dimensional Drawing 7 Specifications 3G3RX A4750 A4900 2 φ12 2 12 300 390 268 700 79 670 357 ...
Страница 362: ...7 13 7 2 Dimensional Drawing 7 Specifications 3G3RX A411K A413K 2 φ12 2 12 380 480 270 740 79 710 480 ...
Страница 369: ...7 20 7 3 Options 7 Specifications 3G3AX RBC4001 3G3AX RBC6001 100 150 280 300 5 70 100 70 150 390 410 5 ...
Страница 392: ......
Страница 393: ...Appendix Appendix 1 Parameter List App 1 Appendix 2 Product Life Curve App 41 Appendix 3 Life Alarm Output App 42 ...
Страница 436: ......
Страница 437: ...Index ...
Страница 441: ......