Summary of Contents for Fuji Electric FVR-C9S-2UX Series

Page 1: ...derutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In s...

Page 2: ...1 FVR C9S 2UX Instruction Manual FVR C9S 2UX Drive Series Three phase 230 VAC Input Type Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 3: ...ase make sure that this instruction manual accompanies the drive to the end user Keep this instruction manual so that it will always be available for the duration of the drive s operating life Product...

Page 4: ...ions 4 1 Inspection Upon Receipt 6 2 Part Names 7 3 Warning and Caution 7 4 Specifications 8 5 External Dimensions 10 6 Installation Instructions 13 7 Wiring 13 8 Basic Wiring Diagrams 15 9 Applicatio...

Page 5: ...drive near flammable materials otherwise fires may result Do not hold the drive by its cover when trans porting The drive could be damaged and cause injury to personnel Do not let any scraps of thread...

Page 6: ...hase and rated input voltage of the drive Using an improper power supply may cause injury or damage to the equipment Do not connect AC power to the output termi nals U V W otherwise injury may result...

Page 7: ...30 Field wiring connection shall be made by a UL listed and CSA Certified closed loop terminal connector sized for the wire gauge involved Connector must be fixed using the crimp tool specified by th...

Page 8: ...nnect power supply only to the power terminals L1 L2 and L3 3 Whenever removing the drive cover al ways switch off the power supply Do not switch on the power supply to the drive with the drive cover...

Page 9: ...y Analog setting 1 0 of max frequency 25 10 C frequency Digital setting 0 01 of max frequency 10 50 C Setting resolution Analog setting 1 255 of max frequency ex 0 25 Hz 60 Hz 0 5 Hz 120 Hz Digital Se...

Page 10: ...DC brake Brake starting frequency 3 Hz fixed Setting of braking current braking time is variable Overload Detects overload current and stops drive Momentary overcurrent Protects drive In case of groun...

Page 11: ...0 0 39 10 0 06 1 5 0 43 11 TERMINAL M3 5 D1 0 24 6 2 0 24 6 2 D D2 0 06 1 5 Rated Current External Dimensions inches mm DWG No Type A D D1 D2 FVRF12C9S 2UX 0 7 2 38 60 5 0 89 22 5 0 39 10 FVRF25C9S 2U...

Page 12: ...118 4 21 107 4 33 110 5 12 130 0 20 5 1 97 50 3 15 80 0 24 6 2 0 45 11 5 0 45 11 5 0 43 11 3 43 87 0 45 11 5 Rated Current External Dimensions inches mm DWG No Type A D D1 D2 FVR002C9S 2UX 7 0 5 14 13...

Page 13: ...0 24 6 2 0 24 6 2 5 45 138 5 2 87 73 0 24 6 2 5 61 168 5 18 157 5 51 140 7 09 180 0 20 5 2 01 51 5 08 129 0 24 6 2 0 45 11 5 0 45 11 5 0 43 11 4 61 117 0 45 11 5 3 78 96 1 0 47 12 2 58 65 5 2 09 53 0...

Page 14: ...or other positional installation will cause the drive to overheat Space The drive will generate heat during operation Allow sufficient space around the unit as shown in the above figure Mounting plate...

Page 15: ...te 2 In case of using an external potenti ometer remove the connector by which the keypad panel and the CN2 on the drive main unit are connected 5 Reinstall the cover Connect the harness of the keypad...

Page 16: ...ad panel The RUN STOP function of the drive is controlled by the RUN STOP keys on the keypad panel M FAB 8 8 8 CN2 10V 1mA L1 L2 L3 U V W 13 12 11 FWD REV RST BX CM THR FM E G Power Supply AC200 230V...

Page 17: ...E G M L1 L2 L3 13 12 11 x CN2 8 8 8 FVR C9S Reverse direction operation command Motor coast to stop command External alarm input Analog monitor 10V 1mA Alarm reset 30A 30B 30C Fault Note 1 Set functio...

Page 18: ...If the control circuit wiring must cross the main circuit wiring make sure it crosses at a right angle Use shielded twisted wire for the control circuit wiring which should be as short as possible 65...

Page 19: ...Drive decelerates and stops when FWD CM is opened REV Reverse Stop Command Input Terminal Reverse direction operation takes place when REV CM is closed Drive decelerates and stops when REV CM is open...

Page 20: ...nternal resistance of 10K ohm or greater can be connected In case of DC ammeter 1mA full scale it is necessary to add series resistance of 10K ohm 1 2W This output is a pulse output constant frequency...

Page 21: ...ncy setting can be performed by turning the potentiometer control knob on the keypad panel Turn the potentiometer control knob clockwise to increase frequency Frequency setting by digital signal F01 0...

Page 22: ...1 3 F 0 1 0 4 0 2 1 F 0 1 1 C92 07 The frequency setting rate of change increases when FUNC DATA key and UP DOWN keys are pressed simultaneously F RUN STOP Keypad panel operation RUN STOP Keys Termin...

Page 23: ...during operation This key does not function when terminal opera tion control F02_ _ 1 is selected STOP key This key is used for stopping operation This key does not function when terminal opera tion...

Page 24: ...key to select function code F 0 1 3 FUNC DATA Press this key to display function code 1 4 UP DOWN Press UP key or DOWN key to change function code data 1 5 FUNC DATA Press this key to store data F 0...

Page 25: ...Yes F06 Deceleration Time 0 0 60s 0 0 setting 0 01s s 0 1 6 0s Yes F07 Torque Boost 0 31 code 13 Yes F08 Electronic Thermal Overload Relay Operation 0 Inactive 1 Active standard 4 pole motor 2 Active...

Page 26: ...20 Hz Hz 1 0 Yes F24 High Limiter 0 100 1 100 Yes F25 Low Limiter 0 100 1 0 Yes F26 Bias Setting 0 100 1 0 Yes F27 THR Terminal Function 0 External alarm input 1 Multistep speed selection X1 0 No F28...

Page 27: ...which is the divergent point of the specified torque characteristics and the specified output characteristics 5 0 Frequency can be set in increments of 1 Hz within a range of 50 to 120 Hz 1 2 0 Set to...

Page 28: ...lay protection For a Fuji FV motor F 0 9 Electronic Thermal Overload Relay Level Sets the operation level for the electronic thermal overload relay 3 0 Setting range 30 to 105 increments of 1 1 0 5 Mo...

Page 29: ...80 70 60 50 40 30 20 10 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 Drive frequency Hz Setting value Continuously allowable current 105 30 110 100 90 80 70 60 50 40 30 20 10 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8...

Page 30: ...frequency which is a proportional ratio of the analog frequency setting Selects an analog input signal level when F O 1 is _ _ 1 0 Maximum frequency is outputted at 10V 1 Maximum frequency is outputt...

Page 31: ...ows The information for any new trip will be stored in the area for the information for the latest trip shown above each trip history will be removed downward and the information for the third precedi...

Page 32: ...times is fixed at 5 Retry takes place in 0 5s after trip 1 Note that the retry takes place only in the case where the drive is tripped due to overcurrent or overvoltage applied during operation F 1 9...

Page 33: ...nts of 1 within a range of 0 to 100 1 0 0 F 2 7 THR Terminal Function This function enables terminal THR to be used for two different functions by changing the data code as follows 0 External alarm in...

Page 34: ...ed via THR BX terminal function change F27 F28 Note 2 In selecting THR BX terminal function F27 F28 individual setting is possible Speed 0 Frequency setting is made by either the analog signal or the...

Page 35: ...l scale Note The FM terminal output is a pulse output of which frequency is constant 38 1 Hz and duty is variable F 3 3 FM Terminal Function Selection With regard to the data outputted to the FM termi...

Page 36: ...1 Yes External Alarm Input Stops drive by input of an external signal OH2 Yes Electronic Thermal Overload Detects overload of motor and stops drive OL Yes Drive Overload Detects overload of drive and...

Page 37: ...s 12 months after installa tion or 18 months after shipment from the Company whichever occurs first Before calling the number at left to deter mine warranty status the drive serial number will be requ...

Page 38: ...hat Line Reactor on Input Yes No Input Starter Yes No Output Starter Yes No Motor Overloads Yes No Control Terminals Used circle if used THR X1 X2 X3 30A 30B 30C RST BX FWD REV C1 11 12 13 RUN RT1 Fun...

Page 39: ...38 FVR C9S 2UX Notes Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 40: ...39 FVR C9S 2UX Notes Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 41: ...4 98 Printed in USA GE Fuji Drives USA Inc 1501 Roanoke Blvd Suite 435 Salem VA 24153 1 800 543 6196 Internet Address http www ge com Artisan Technology Group Quality Instrumentation Guaranteed 888 88...

Page 42: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Reviews: