![background image](http://html.mh-extra.com/html/omron/3g3rx-series/3g3rx-series_user-manual_742806057.webp)
3-8
3-3 Test Run Operation
3
Operation
No-load Operation
• Start the no-load motor (i.e., not connected to the mechanical system) using the Digital Operator.
Forward/Reverse Rotation via the Digital Operator
• Make sure that no errors have occurred in the Inverter during operation.
• Switch between forward and reverse with the operator rotation direction selection (F004).
Stopping the Motor
• After completing the no-load operation, press the STOP/RESET key. The motor will stop.
Actual Load Operation
• After checking the operation with the motor in the no-load status, connect the mechanical system
and operate with an actual load.
Connecting the Mechanical System
• After confirming that the motor has stopped completely, connect the mechanical system.
• Be sure to tighten all the screws when fixing the motor axis and the mechanical system.
Operation via the Digital Operator
• Because a possible error may occur during operation, make sure that the STOP/RESET key on
the Digital Operator is easily accessible.
• Use the Digital Operator to operate the Inverter the same way as in no-load operation.
Checking the Operating Status
• After making sure that the operating direction is correct and that the Inverter is operating smoothly
at a slow speed, increase the frequency reference.
• By changing the frequency reference or the rotation direction, make sure that there is no vibration
or abnormal sound from the motor.
Make sure that the output current (output current monitor [d002]) is not excessive.
Key sequence
Display example
Description
Press and hold the Mode key for 3 seconds or more to display "d001",
and then press again.
(Monitors the frequency reference.)
Press the RUN key.
The RUN command LED indicator is lit and the monitor value of the
frequency reference is displayed. (Factory default: F001 = 6)
0.0
6.0
Содержание 3G3RX Series
Страница 1: ...Cat No I560 E1 03 USER S MANUAL SYSDRIVE RXSERIES High function General purpose Inverter ...
Страница 2: ......
Страница 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 4 ...
Страница 22: ......
Страница 23: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Wiring 2 6 ...
Страница 48: ......
Страница 108: ......
Страница 324: ......
Страница 325: ...Chapter 5 Maintenance Operations 5 1 Protective Functions and Troubleshooting 5 1 5 2 Warning Function 5 10 ...
Страница 337: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 ...
Страница 348: ......
Страница 349: ...Chapter 7 Specifications 7 1 Standard Specification List 7 1 7 2 Dimensional Drawing 7 6 7 3 Options 7 14 ...
Страница 358: ...7 9 7 2 Dimensional Drawing 7 Specifications 3G3RX A2300 A4300 368 79 265 310 10 510 540 2 φ10 195 45 80 265 ...
Страница 360: ...7 11 7 2 Dimensional Drawing 7 Specifications 3G3RX A2550 380 670 700 2 φ12 12 380 480 250 352 79 ...
Страница 361: ...7 12 7 2 Dimensional Drawing 7 Specifications 3G3RX A4750 A4900 2 φ12 2 12 300 390 268 700 79 670 357 ...
Страница 362: ...7 13 7 2 Dimensional Drawing 7 Specifications 3G3RX A411K A413K 2 φ12 2 12 380 480 270 740 79 710 480 ...
Страница 369: ...7 20 7 3 Options 7 Specifications 3G3AX RBC4001 3G3AX RBC6001 100 150 280 300 5 70 100 70 150 390 410 5 ...
Страница 392: ......
Страница 393: ...Appendix Appendix 1 Parameter List App 1 Appendix 2 Product Life Curve App 41 Appendix 3 Life Alarm Output App 42 ...
Страница 436: ......
Страница 437: ...Index ...
Страница 441: ......