6-2
6-1 Inspection and Maintenance
6
Inspection and Mai
n
tenance
Daily Inspection
• Basically, check the following during operation.
• The motor operates according to the settings.
• There are no errors in the installation environment.
• There are no errors in the cooling system.
• There are no abnormal vibrations or sounds.
• There are no abnormal overheat or discoloration.
• There are no abnormal odors.
• Check the input voltage of the Inverter during operation using a tester or other equipment.
• There is no frequent power supply voltage fluctuation.
• The voltage level between the wires is balanced.
Cleaning
• Always keep the Inverter clean for operation.
• Lightly remove any dirt with a soft cloth moistened with a neutral detergent.
Note:
Do not use such solutions as acetone, benzene, toluene, or alcohol for cleaning. Doing so may
cause the Inverter surface to dissolve or its coating to come off.
Do not use any detergent or alcohol to clean the Digital Operator display.
Periodic Inspection
• Check the parts that cannot be checked without stopping operation, as well as those that require
periodic inspection.
• Contact OMRON Corporation for periodic inspections.
• Check that there are no errors in the cooling system.
.......... Clean the air filter.
• Check that all parts that need tightening are secure.
.......... Screws and bolts may become loose because of vibration or temperature change.
• Check that there is no corrosion or damage to the conductors and/or insulators.
• Measurement of insulation resistance.
• Check and replace the cooling fan, smoothing capacitor, and relay.
Содержание 3G3RX Series
Страница 1: ...Cat No I560 E1 03 USER S MANUAL SYSDRIVE RXSERIES High function General purpose Inverter ...
Страница 2: ......
Страница 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 4 ...
Страница 22: ......
Страница 23: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Wiring 2 6 ...
Страница 48: ......
Страница 108: ......
Страница 324: ......
Страница 325: ...Chapter 5 Maintenance Operations 5 1 Protective Functions and Troubleshooting 5 1 5 2 Warning Function 5 10 ...
Страница 337: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 ...
Страница 348: ......
Страница 349: ...Chapter 7 Specifications 7 1 Standard Specification List 7 1 7 2 Dimensional Drawing 7 6 7 3 Options 7 14 ...
Страница 358: ...7 9 7 2 Dimensional Drawing 7 Specifications 3G3RX A2300 A4300 368 79 265 310 10 510 540 2 φ10 195 45 80 265 ...
Страница 360: ...7 11 7 2 Dimensional Drawing 7 Specifications 3G3RX A2550 380 670 700 2 φ12 12 380 480 250 352 79 ...
Страница 361: ...7 12 7 2 Dimensional Drawing 7 Specifications 3G3RX A4750 A4900 2 φ12 2 12 300 390 268 700 79 670 357 ...
Страница 362: ...7 13 7 2 Dimensional Drawing 7 Specifications 3G3RX A411K A413K 2 φ12 2 12 380 480 270 740 79 710 480 ...
Страница 369: ...7 20 7 3 Options 7 Specifications 3G3AX RBC4001 3G3AX RBC6001 100 150 280 300 5 70 100 70 150 390 410 5 ...
Страница 392: ......
Страница 393: ...Appendix Appendix 1 Parameter List App 1 Appendix 2 Product Life Curve App 41 Appendix 3 Life Alarm Output App 42 ...
Страница 436: ......
Страница 437: ...Index ...
Страница 441: ......