This document is supplied with Model KBVF-22D (Part No. 9572).

IMPORTANT: The following information and instructions are to be used as a supplement to the KBVF Installation and Operation Manual (Part
No. A40288) until the new manual is available with the addition of Model KBVF-22D (Part No. 9572).  The  KBVF Series has been changed to
a second generation version (2G).  The General Performance Specifications have not changed.  This 2G version has an additional Frequency
Multiplier Jumper, a single Input Line Voltage Selection Jumper, and an additional connector for accessories.  The KBVF manual must be read
and understood before attempting to operate this control.  For further assistance, contact our Sales Department at 954-346-4900 or Toll Free
at 800-221-6570 (outside Florida).
Also see KBVF 2G Version Supplemental Connection Diagrams and Jumper Settings (Part No. A40090G).

Table 1 - Electrical Ratings

AC Line Input

Motor Output

Model

Part No.

Volts AC

(50/60 Hz)

Maximum

Current

(Amps AC)

Voltage Range

(Volts AC)

Maximum

Continuous Load Current

(RMS Amps/Phase)

Maximum

Horsepower

(HP (kW))

115

6.0

KBVF-22D

9572

208/230

3.8

0 - 230

  1.5 *

¼ (.18)

* CL Trimpot Range (Amps AC): 0.9 - 2.8 (Factory Setting: 2.4).

Figure 1 - Mechanical Specifications (Inches/mm) and Control Layout

(Shown without Factory Installed Finger-Safe Cover)

Enlarged View of Jumpers and Trimpots

1

Setting Selectable Jumpers
This control has selectable jumpers which may have to be set  before  the control can  be  used.   See Figure  1,  above,  for  the location  of
jumpers.  WARNING! Disconnect the AC line before changing position of jumpers.
See Section III, on pages 14 - 16 of the manual.

1.1

AC Line Input Voltage Selection (Jumper J1 on Upper PC Board): This control can operate standard 208 - 230 Volt AC - 50/60

 

 "!#!%$&'()*'(,+-.

/"$(0*1#(234!

5768.

9

:#;3< =.

,>?

@3=:/>&AB>

208/230 Volt AC line input (Jumper J1 in the "230V" position).  To operate the control from a 115 Volt AC line input, set Jumper J1
to the "115V" position.  See Figure 2, on page 2.

Summary of Contents for 9572

Page 1: ... 4900 or Toll Free at 800 221 6570 outside Florida Also see KBVF 2G Version Supplemental Connection Diagrams and Jumper Settings Part No A40090G Table 1 Electrical Ratings AC Line Input Motor Output Model Part No Volts AC 50 60 Hz Maximum Current Amps AC Voltage Range Volts AC Maximum Continuous Load Current RMS Amps Phase Maximum Horsepower HP kW 115 6 0 KBVF 22D 9572 208 230 3 8 0 230 1 5 18 CL ...

Page 2: ...position To operate 50 Hz motors up to 100 Hz set Jumper J1 to the 50Hz position and set Jumper J2 to the X2 position Note In Overspeed Mode the motor will produce full rated torque up to the motor s rated frequency Operating the motor above it s rated frequency will linearly reduce the motor torque to 50 at full output frequency 120 Hz for 60 Hz motors and 100 Hz for 50 Hz motors Figure 3 Motor F...

Page 3: ...Status Indicator 22 IX Trimpot Adjustments 24 X Limited Warranty 30 TABLES 1 General Performance Specifications 5 6 2 Electrical Ratings 7 3 Terminal Wiring Information 17 4 Fuse Selection Chart 21 5 KBVF Status Indicators 22 23 6 CL Setpoint vs Trip Time 27 FIGURES 1 Maximum Allowed Motor Torque vs Speed 8 Figures Continued Page 2 Motor with External Cooling 8 3 Control Layout 9 4A KBVF HP Mechan...

Page 4: ... control chassis 2 MOTOR LEADS Connect the three motor leads to terminals U V and W Be sure motor is wired for proper voltage 208 230VAC only Motor cable length should not exceed 100 feet special reactors may be required consult factory 1 3 MOTOR FREQUENCY SELECTION Control is factory set for 60 Hz and 50 60 Hz motors For 50 Hz motors completely remove jumper J1 on lower PC board Note In 50 Hz mod...

Page 5: ...ves pertinent at the time of manufacture Contact factory for detailed installation instructions and Declaration of Conformity Installation of a CE approved RFI filter KBRF 200A KB P N 9945A or equivalent is required Additional shielded motor cable and or AC line cables may be required along with a signal isolator SIVF KB P N 9474 or equivalent I GENERAL INFORMATION The KBVF Adjustable Frequency Dr...

Page 6: ...e of frequency setting 70 110 100 Speed Range ratio 50 1 Isolated Input Signal must be used 5 General Performance Specifications Continued Parameter Specification Factory Setting Acceleration Trimpot Range secs 3 20 1 5 Deceleration Trimpot Range secs 3 20 1 5 Boost Trimpot Range 50 Hz only 6 30 Slip Compensation Trimpot Range Volts Hz Amp 0 3 1 5 Current Limit Trimpot Range HP amps AC 1 5 4 5 3 8...

Page 7: ... over a wider speed range Consult motor manufacturer for details WARNING There may be some motors whose characteristics may cause overheating and winding failure under light load or no load conditions If the motor is operated in this manner for an extended period of time it is recommended that the unloaded motor amperage be checked from 2 15 Hz 60 450 RPM to ensure motor current does not exceed th...

Page 8: ...FIG 3 CONTROL LAYOUT Illustrates factory setting of jumpers and approximate setting of trimpots 9 FIG 4A KBVF HP MECHANICAL SPECIFICATIONS INCHES mm 10 ...

Page 9: ...FIG 4B KBVF HP MECHANICAL SPECIFICATIONS INCHES mm 11 FIG 5A KBVF 1 HP MECHANICAL SPECIFICATIONS INCHES mm 12 ...

Page 10: ...OLTS Warning Do not change jumper position with AC line connected Be sure proper input voltage is applied to control corresponding to jumper setting Connecting 230VAC to a 115VAC control input will permanently damage control 115VAC and 230VAC labels are provided Use the appropriate label to identify the correct input voltage after setting jumpers B Motor Frequency The controls are factory set to o...

Page 11: ... green to Red Yellow flash approximately 15 seconds 2 Turning the main speed pot to zero MIN speed trimpot must be set to zero speed in order to reset with main speed pot 3 Use Enable contact See section V F on page 20 Note If the control trips in I2 t the motor may be overloaded Check motor current with an AC ammeter Use RMS responding meter Also the CL setting may be set too low see sec IX E p 2...

Page 12: ...l Designation Connection Designation Type of Connector Supply Wire Gauge Minimum Maximum AC Line L1 L2 1 4 QD 16 14 Motor U V W 1 4 QD 16 14 Potentiometer P1 P2 P3 1 4 QD 22 18 17 A AC Line Wire the correct input AC line voltage 115 230VAC 50 60 Hz to terminals L1 and L2 depending on model number and jumper selection for dual voltage models Be sure to connect proper input voltage to control catast...

Page 13: ...rimpot must be turned to zero CCW If 0 10VDC operation is required a resistor network can be added as per fig 10C If an isolated signal is not available a separate signal isolator must be used KBSI 240D or equivalent Do not ground earth signal wiring 19 E Manual Start Mode To operate in the manual start mode the A M jumper must be removed and the 2 wire connector supplied must be installed The con...

Page 14: ...fy proper operation See sec VIII p 22 21 TABLE 5 KBVF STATUS INDICATORS LED Ref Function State 1 LED Color ST Status Normal Control Operation Slow Flash Green CL current limit Steady Red I2 t Quick Flash Red Short Circuit slow Flash Red Undervoltage Quick Flash Red Yellow Overvoltage Slow Flash Red Yellow Stop Steady Yellow PWR Power Bus Power Supply Steady Green VIII LED STATUS INDICATORS The KBV...

Page 15: ...se controls contain trimpots which have been factory adjusted for most applications Paragraph 4 on page 2 illustrates the location of the trimpots and their approximate adjustment positions Some applications may require readjustment of the trimpots in order to tailor the control to exact requirements See table 1 pages 5 and 6 for range and factory setting of trimpots Readjust trimpots as follows W...

Page 16: ...ired for application Note When the control is set for 50 Hz operation the DEC trimpot will automatically change to Adjustable Boost See sec IX G p 28 25 Application Note On applications with high inertial loads the deceleration may automatically increase in time This will slow down the rate of speed decrease to prevent the D C bus voltage from rising to the overvoltage trip point This function is ...

Page 17: ...ries with one motor phase 27 2 Run motor and set unloaded speed to approximately 50 speed 900 RPM on 4 pole 1500 1725 RPM motors Using a tachometer record unloaded speed 3 Load motor to rated motor nameplate current AC amps 4 Adjust COMP trimpot so that loaded RPM is equal to unloaded RPM 5 Motor is now compensated to provide constant speed under varying loads G Boost When the control is set for 5...

Page 18: ...to be defective in material or workmanship This warranty is valid if the unit has not been tampered with by unauthorized persons misused abused or improperly installed and has been used in accordance with the instructions and or ratings supplied The foregoing is in lieu of any other warranty or guarantee expressed or implied and we are not responsible for any expense including installation and rem...

Reviews: