When the Option Board responds with the result, process the response:
Step 10
Instruct the Option Board to change Inverter parameter F002 (Acceleration
time 1) to 3.00 sec:
When the Option Board responds with the result, process the response:
Step 11
Close the DP-V1 Class 2 (MSAC2) channel (Refer to section
4-5-2-1 Opening
and Closing a DP-V1 Channel
)
Table 65 DP-V1 Class 2 Write-Parameter Read Instruction F002
Word offset
DP Head
er
MSAC2_W
rite
+0
+1
+2
+3
+4
DP T
rai
ler
Description
Request Header
Parameter Address
REF RT DO
N
PA
CA
PNU
IND
Message
data
[hex]
08
01
01
01
10
01
1772
0000
[dec]
8
1
1
1
16
0
6002
0
Request reference
(user parameter)
Parameter F002
Address value (non-array)
Parameter read instruction
Addressing a value
1
st
Inverter attached to Option Board
1 parameter address to follow
Table 66 DP-V1 Class 2 Read-Result of F002 Read Instruction
Word offset
DP H
ead
er
MSAC
2_Re
ad
+0
+1
+2
+3
+4
DP T
railer
Description
Request Header
Value
REF RT DO
N
FMT CV
DATA
Message
data
[hex]
08
01
01
01
42
01
0000
03E8
[dec]
8
1
1
1
66
1
1000
Request reference
Value = 10.00s
Parameter read success
1
st
Inverter attached to Option Board
1 value
1 parameter processed
DATA format = WORD
Table 67 DP-V1 Class 2 Write-Parameter Change Instruction F002
Word offset
DP H
e
ad
er
MSAC
2_W
rite
+0
+1
+2
+3
+4
+5
+6
+7
DP T
rai
le
r
Description
Request Parameter
Address
Value
data
R RT D N PA C PNU
IND
F C
DATA
Message
data
[hex]
09 02 01 01 10 01 1771 0000 43 01 0000 012C
[dec]
9 2 1 1 16 1 6001
0
67 1
300
Request reference
Value = 3.00s
Parameter change instruction
Element 001.0
1
st
Inverter attached to Option
1 element
1 parameter address and value to follow
DATA format=DWORD
Addressing a value
1 value
Table 68 DP-V1 Class 2 Read-Result of F002 Change Instruction
Word offset
DP Hea
d
er
MSAC2_
Read
+0
+1
DP T
rai
ler
Description
Request Header
REF
RT
DO
N
Message
data
[hex]
09
02
01
01
[dec]
9
2
1
1
Request reference
1 parameter processed
Parameter change success
1
st
Inverter attached to Option Board
I111E-EN-02+3G3AX-MX2-RX-PRT+OperManual.book Seite 50 Donnerstag, 8. September 2011 11:53 11
Содержание 3G3AX-MX2-PRT-E
Страница 1: ...MX2 RX PROFIBUS Option Board Model 3G3AX MX2 PRT E 3G3AX RX PRT E USER S Manual Cat No I111E EN 02...
Страница 6: ...vi...
Страница 14: ...xiv Compliance with EC Directives...
Страница 20: ...6 Introduction to PROFIBUS Section 1 3...
Страница 36: ...22 How to mount the Option Board on the Inverter Section 2 3...
Страница 42: ...28 Configuring the Network Section 3 2...
Страница 70: ...56 Limitations Caused by Inverter Mode and Rating Selection Section 4 7...
Страница 108: ...94 APPENDIX G...
Страница 110: ...96 APPENDIX H...
Страница 113: ...97...
Страница 115: ......