29
Section
SECTION 4
Operations and Monitoring
This section provides some common usage examples to help you get started.
Unless otherwise specified, all usage examples make use of the PROFIdrive
device profile and associated modules (Refer to section
3-1 Configuring the
Option Board
,
Step 1
). Prepare the Inverter and Option Board before starting
with the usage examples:
Step 1
Initialize the Inverter mode to Induction Motor, Constant Torque:
Set b171 = 1 and then b180 = 1, set b049 = 0.
Refer to MX2 User’s manual (Cat. No. I570) section 3-6-24.
Set b084 = 2 and then b180 = 1, set b049 = 0.
Refer to RX User’s manual (Cat. No. I560) section 4-2 Parameter Initializa-
tion).
Step 2
Configure the Option Board and Network as explained in sections
3-1 Config-
uring the Option Board
and
3-2 Configuring the Network
, but limit the follow-
ing choices:
• When selecting the device profile when configuring the Option Board
(
Step 1
of section
3-1 Configuring the Option Board
), select the PROFId-
rive device profile by setting P182 to 0.
• When configuring the process area content (of section
3-1 Configuring
the Option Board
), set all parameters (P160 - P179 to 0).
• When choosing the module while configuring the network (
Step 6
of sec-
tion
3-2 Configuring the Network
), select either the PPO Type 2 or PPO
Type 5 module.
If you configured everything correctly, your output and input process areas
should contain the following data:
Table 14 Output Process Area
!WARNING
A revision AAAA Inverter allows the motor to run immediately if a trip condition
is reset, and at the same time, Run (STW) is set. For safe operation clear Run
(STW) when you detect a rising-edge on Flt (ZSW). Refer to section 1-1-2
Inverter Support to determine the Inverter revision.
dec
hex
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
-
-
-
-
-
Ovr JR JF Rst
-
-
Run
En
-
-
-
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
En
Run
Run operation
Run enable
JF
Jog run forward
Rst
Fault reset
PKE
IND
Task ID and parameter number
Parameter index
Ovr
Control override
JR
Jog run reverse
HSW
PWE
STW
Parameter value
Control word
Frequency reference
Value
-
+4
-
-
-
+9
STW
HSW
+8
IND
Register
Word offset
+1
+0
PKE
0
0
0
PWE
0
+6
+7
+2
+3
+5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Value
0
00000000
Name
0
Bit
0
0000
I111E-EN-02+3G3AX-MX2-RX-PRT+OperManual.book Seite 29 Donnerstag, 8. September 2011 11:53 11
Содержание 3G3AX-MX2-PRT-E
Страница 1: ...MX2 RX PROFIBUS Option Board Model 3G3AX MX2 PRT E 3G3AX RX PRT E USER S Manual Cat No I111E EN 02...
Страница 6: ...vi...
Страница 14: ...xiv Compliance with EC Directives...
Страница 20: ...6 Introduction to PROFIBUS Section 1 3...
Страница 36: ...22 How to mount the Option Board on the Inverter Section 2 3...
Страница 42: ...28 Configuring the Network Section 3 2...
Страница 70: ...56 Limitations Caused by Inverter Mode and Rating Selection Section 4 7...
Страница 108: ...94 APPENDIX G...
Страница 110: ...96 APPENDIX H...
Страница 113: ...97...
Страница 115: ......