11
How to mount the Option Board on the Inverter
Section 2-3
2-3-1
Mounting sequence of the Option Board on the MX2 Inverter
Step 1
Loosen the screw of the option board
cover, remove the cover and put the
cover aside.
Step 2
For Inverters up to 4.0 kW only:
loosen the screws of the terminal
block cover and remove the cover to
enable access to the chassis ground
terminal screws.
Step 3
Secure the Option Board grounding cable to the Inverter with a mounting
screw.
3-phase 200 V 0.1 - 3.7 kW
3-phase 400 V 0.4 - 4.0 kW
1-phase 200 V 0.1 - 2.2 kW
3-phase 200 V 5.5 - 15 kW
3-phase 400 V 5.5 - 15 kW
I111E-EN-02+3G3AX-MX2-RX-PRT+OperManual.book Seite 11 Donnerstag, 8. September 2011 11:53 11