76
I/O Mapping
APPENDIX B
B-1
I/O Mapping
Note 1
If no Word Offset is specified for a Register, the Register does not exist in the
Input and Output Areas for the Module Type:
The Modbus addresses for the MX2 Inverter are listed in section B-4-2 of the
MX2 user's manual.
The Modbus addresses for the RX Inverter are listed in section 5 of the RX
user's manual.
P160-P169 can also be accessed as PNU915.1 - PNU915.10
P170-P179 can also be accessed as PNU916.1 - PNU916.10
Table B-1 PPO format I/O Mapping
Word Offset
*1
Content
*2
PPO1
PPO2
PPO3
PPO4
PPO5
Output Area
Input Area
+0
+0
+0
PKE
Task ID and Parameter num-
ber
PKE
Task ID and Parameter num-
ber
+1
+1
+1
IND
PNU index / Parameter
group in high byte
IND
PNU index / Parameter
group in high byte
+2
+2
+2
PWE
High word of value
PWE
High word of value
+3
+3
+3
Low word of value
Low word of value or Error
number
+4
+4
+0
+0
+4
PZD1 Modbus register set by P160
or STW if P160 = 0
PZD1 Modbus register set by P170
or ZSW if P170 = 0
+5
+5
+1
+1
+5
PZD2 Modbus register set by P161
or HSW if P161 = 0
PZD2 Modbus register set by P171
or HIW if P171 = 0
+6
+2
+6
PZD3 Modbus register set by P162
or ignored if P162 = 0
PZD3 Modbus register set by P172
or always 0 if P172 = 0
+7
+3
+7
PZD4 Modbus register set by P163
or ignored if P163 = 0
PZD4 Modbus register set by P173
or always 0 if P173 = 0
+8
+4
+8
PZD5 Modbus register set by P164
or ignored if P164 = 0
PZD5 Modbus register set by P174
or always 0 if P174 = 0
+9
+5
+9
PZD6 Modbus register set by P165
or ignored if P165 = 0
PZD6 Modbus register set by P175
or always 0 if P175 = 0
+10
PZD7 Modbus register set by P166
or ignored if P166 = 0
PZD7 Modbus register set by P176
or always 0 if P176 = 0
+11
PZD8 Modbus register set by P167
or ignored if P167 = 0
PZD8 Modbus register set by P177
or always 0 if P177 = 0
+12
PZD9 Modbus register set by P168
or ignored if P168 = 0
PZD9 Modbus register set by P178
or always 0 if P178 = 0
+13
PZD1
0
Modbus register set by P169
or ignored if P169 = 0
PZD1
0
Modbus register set by P179
or always 0 if P179 = 0
I111E-EN-02+3G3AX-MX2-RX-PRT+OperManual.book Seite 76 Donnerstag, 8. September 2011 11:53 11
Содержание 3G3AX-MX2-PRT-E
Страница 1: ...MX2 RX PROFIBUS Option Board Model 3G3AX MX2 PRT E 3G3AX RX PRT E USER S Manual Cat No I111E EN 02...
Страница 6: ...vi...
Страница 14: ...xiv Compliance with EC Directives...
Страница 20: ...6 Introduction to PROFIBUS Section 1 3...
Страница 36: ...22 How to mount the Option Board on the Inverter Section 2 3...
Страница 42: ...28 Configuring the Network Section 3 2...
Страница 70: ...56 Limitations Caused by Inverter Mode and Rating Selection Section 4 7...
Страница 108: ...94 APPENDIX G...
Страница 110: ...96 APPENDIX H...
Страница 113: ...97...
Страница 115: ......