Process Unit Indicator
Process Unit Indicator
Upper Display,
to display process value,
menu symbol and error code etc.
Upper Display,
to display process value,
menu symbol and error code etc.
Lower Display,
to display set point value,
parameter value or control
output value etc.
Lower Display,
to display set point value,
parameter value or control
output value etc.
3 Buttons for ease of control
setup and set point adjustment.
3 Buttons for ease of control
setup and set point adjustment.
Output 1 Indicator
Output 1 Indicator
Table 1.2 Keypad Operation
Table 1.2 Keypad Operation
For a number with decimal point the
display will be shifted one digit right:
For a number with decimal point the
display will be shifted one digit right:
-19999 will be displayed by:
-19999 will be displayed by:
45536 will be displayed by:
45536 will be displayed by:
-9999 will be displayed by:
-9999 will be displayed by:
The unit is programmed by using three keys on the front panel. The available key functions are listed in following table.
The unit is programmed by using three keys on the front panel. The available key functions are listed in following table.
Press and release quickly to increase the value of parameter.
Press and hold to accelerate increment speed.
Press and release quickly to decrease the value of parameter.
Press and hold to accelerate decrement speed.
Select the parameter in a direct sequence.
Allow access to more parameters on user menu, also used to Enter manual
mode, auto-tune mode, default setting mode and to save calibration data
during calibration procedure.
Select the parameter in a reverse sequence during menu scrolling.
Select the operation Mode in sequence.
Reset the front panel display to a normal display mode, also used to leave
the specific Mode execution to end up the auto-tune and manual control
execution, and to quit the sleep mode.
The controller enters the sleep mode if the sleep function ( SLEP ) is enabled
( select YES ).
By entering correct security code to allow execution of engineering programs.
This function is used only at the factory to manage the diagnostic reports.
The user should never attempt to operate this function.
Press
for at least 3 seconds
Press
for at least 6 seconds
Press
Press
Press
Press
Press
for at least 3 seconds
Up Key
Down Key
Scroll Key
Enter Key
Start Record Key
Reverse Scroll Key
Mode Key
Reset Key
Sleep Key
Factory Key
TOUCHKEYS
FUNCTION
DESCRIPTION
Reset historical values of PVHI and PVLO and start to record the peak process
value.
How to display a 5-digit number ?
How to display a 5-digit number ?
9
1 4 Keys and Displays
1 4 Keys and Displays
: Characters displayed with symbols
: Characters displayed with symbols
Figure 1.4 Front Panel Description
Figure 1.4 Front Panel Description
Table 1.3 Character Legend
Table 1.3 Character Legend
-199.99 will be displayed by -199.9
4553.6 will be displayed by 4553
-199.99 will be displayed by -199.9
4553.6 will be displayed by 4553
For a number without decimal point
the display will be divided into two
alternating phases:
For a number without decimal point
the display will be divided into two
alternating phases:
A
E
I
N
S
X
B
F
J
O
T
Y
C
G
K
P
U
Z
c
H
L
Q
V
?
D
h
M
R
W
=
Output 2 Indicator
Output 2 Indicator
Alarm 1 Indicator
Alarm 1 Indicator
Alarm 2 Indicator
Alarm 2 Indicator
ETR-8300
Out1 Out2
Alm1 Alm2