Chapter 2 Installation
Chapter 2 Installation
2 2 Mounting
2 2 Mounting
2 1 Unpacking
2 1 Unpacking
Upon receipt of the shipment remove the unit from the carton and inspect the
unit for shipping damage. If any damage due to transit , report and file a claim
with the carrier. Write down the model number, serial number, and date code for
future reference when corresponding with our service center. The serial number
(S/N) and date code (D/C) are labeled on the box and the housing of control.
Upon receipt of the shipment remove the unit from the carton and inspect the
unit for shipping damage. If any damage due to transit , report and file a claim
with the carrier. Write down the model number, serial number, and date code for
future reference when corresponding with our service center. The serial number
(S/N) and date code (D/C) are labeled on the box and the housing of control.
Make panel cutout to dimension shown in Figure 2.1.
Make panel cutout to dimension shown in Figure 2.1.
Figure 2.1 Mounting Dimensions
Figure 2.1 Mounting Dimensions
Dangerous voltages capable of causing death are sometimes present
in this instrument. Before installation or beginning any troubleshooting
procedures the power to all equipment must be switched off and isolated. Units
suspected of being faulty must be disconnected and removed to a properly
equipped workshop for testing and repair. Component replacement and internal
adjustments must be made by a qualified maintenance person only.
Dangerous voltages capable of causing death are sometimes present
in this instrument. Before installation or beginning any troubleshooting
procedures the power to all equipment must be switched off and isolated. Units
suspected of being faulty must be disconnected and removed to a properly
equipped workshop for testing and repair. Component replacement and internal
adjustments must be made by a qualified maintenance person only.
To minimize the possibility of fire or shock hazards, do not expose this
instrument to rain or excessive moisture. This control is not to be used in hazardous
locations as defined in Article 500 and 505 of the national electric code.
To minimize the possibility of fire or shock hazards, do not expose this
instrument to rain or excessive moisture. This control is not to be used in hazardous
locations as defined in Article 500 and 505 of the national electric code.
Do not use this instrument in areas under hazardous conditions such as
excessive shock, vibration, dirt, moisture, corrosive gases or oil. The ambient
temperature of the areas should not exceed the maximum rating specified in Chapter 8.
Do not use this instrument in areas under hazardous conditions such as
excessive shock, vibration, dirt, moisture, corrosive gases or oil. The ambient
temperature of the areas should not exceed the maximum rating specified in Chapter 8.
21
92
mm
45 mm
Panel Cutout
65 mm
Panel
Set both mounting assembly options aside and insert the controller into panel
cutout. Install either the mounting clamp or screw set into provided grooves.
Gently tighten the screws or slide the clamp till the controller’s front panel is
snug against the front of the cutout.
Set both mounting assembly options aside and insert the controller into panel
cutout. Install either the mounting clamp or screw set into provided grooves.
Gently tighten the screws or slide the clamp till the controller’s front panel is
snug against the front of the cutout.