Chapter 17: LPC800 SPI0/1
17.6.1 SPI Configuration register
The CFG register contains information for the general configuration of the SPI. Typically,
this information is not changed during operation. Some configurations, such as CPOL,
CPHA, and LSBF should not be made while the SPI is not fully idle. See the description of
the Idle status (in
) for more information.
Remark:
If the interface is re-configured from Master mode to Slave mode or the reverse
(an unusual case), the SPI should be disabled and re-enabled with the new configuration.
Table 189. SPI Configuration register (CFG, addresses 0x4005 8000 (SPI0) , 0x4005 C000 (SPI1)) bit
description
Bit
Symbol
Value Description
Reset
value
0
Enable
SPI enable.
0
0
Disabled. The SPI is disabled and the internal state machine and counters are reset.
1
Enabled. The SPI is enabled for operation.
1
-
Reserved. Read value is undefined, only zero should be written.
NA
2
Master
Master mode select.
0
0
Slave mode. The SPI will operate in slave mode. SCK, MOSI, and the SSEL signals are
inputs, MISO is an output.
1
Master mode. The SPI will operate in master mode. SCK, MOSI, and the SSEL signals
are outputs, MISO is an input.
3
LSBF
LSB First mode enable.
0
0
Standard. Data is transmitted and received in standard MSB first order.
1
Reverse. Data is transmitted and received in reverse order (LSB first).
4
CPHA
Clock Phase select.
0
0
Change. The SPI captures serial data on the first clock transition of the frame (when the
clock changes away from the rest state). Data is changed on the following edge.
1
Capture. The SPI changes serial data on the first clock transition of the frame (when the
clock changes away from the rest state). Data is captured on the following edge.
5
CPOL
Clock Polarity select.
0
0
Low. The rest state of the clock (between frames) is low.
1
High. The rest state of the clock (between frames) is high.
6
-
Reserved. Read value is undefined, only zero should be written.
NA
7
LOOP
Loopback mode enable. Loopback mode applies only to Master mode, and connects
transmit and receive data connected together to allow simple software testing.
0
0
Disabled.
1
Enabled.
8
SPOL
SSEL Polarity select.
0
0
Low. The SSEL pin is active low. The value in the SSEL fields of the RXDAT, TXDATCTL,
and TXCTL registers related to SSEL is not inverted relative to the pins.
1
High. The SSEL pin is active high. The value in the SSEL fields of the RXDAT,
TXDATCTL, and TXCTL registers related to SSEL is inverted relative to the pins.
31:9
-
Reserved. Read value is undefined, only zero should be written.
NA