Ts Series Installation and Operation Instructions
│
Trinity Ts
11
Termination Options
The venting system of the Ts80 may be terminated using field supplied piping to construct a “Two-Pipe”
termination, see Figures 4-3, 4-4a, 4-6, 4-9, 4-10 and 4-11. Alternatively, the venting may be terminated used a
factory kit, either “Concentric” (see Figures 4-2, 4-4b, 4-5 and 4-7) or “Low Profile” (see Figure 4-8). The
Concentric Vent Termination Kit can be either Roof or Sidewall terminated, while the Low Profile Termination
Kit may only be Sidewall terminated. See Table 4-5 for details on the optional termination kits.
Venting Options -
Due to potential moisture loading (build-up) along the exterior wall,
sidewall venting may not be the preferred venting option. See Figs 4-2(b) and 4-3(b).
Optional Termination Kits
Kits certified with the Trinity Ts80 are listed in Table 4-5 and available from IPEX and/or NTI. For more
information on System 636 Concentric Vent Kits or wholesaler locations contact IPEX directly.
USA:
1-800-463-
9572 or www.IPEXamerica.com
│
CAN:
1-866-473-9462 or
www.ipexinc.com
.
Table 4-5 Optional Vent Termination Kits
Vent Option
NTI
P/N
IPEX
P/N
Description
1,2,4
Vent Kit
Material
Kit
Connection
Roof
Wall
82666 n/a Concentric Vent Termination Kit (US)
3,6
PVC
3"
3
3
n/a
196006
3"
84355
196021
Concentric Vent Termination Kit (CAN)
5,7
ULC
S636
PVC
4"
3
3
n/a
197009 Concentric Vent Termination Kit (CAN)
5,7
ULC S636
CPVC
3"
3
3
84357 196985
3"
84358 196986
Low Profile Termination Kit
(Flush Mount)
PVC
4"
2
3
Notes:
1
Instructions included with termination kits contain more detailed assembly and installation instructions.
2
Clearance requirements in this manual supersede those of the instructions included with the vent terminal.
3
York part number 1CT0303 for NTI Kit part number 82666.
4
Terminal
MUST
be cemented together and to the vent pipes during installation.
5
Certified to ULC System 636.
6
NTI Kit part number 82666 (York part number 1CT0303) is no longer approved for use in Canada.
7
Vent Screens sold separately for IPEX Concentric Vent Kits (3" vent screen P/N 196051; 4" vent screen P/N 196052).
Содержание TRINITY Ts80
Страница 38: ...Trinity Ts Installation and Operation Instructions Ts Series 38 Figure 11 2 Ts80 Model Low Voltage Field Wiring...
Страница 40: ...Trinity Ts Installation and Operation Instructions Ts Series 40 Figure 12 1 b Ts80 Ladder Logic Diagram...
Страница 48: ...Trinity Ts Installation and Operation Instructions Ts Series 48 Figure 13 4 Diagnostic Mode Screens...
Страница 73: ...Ts Series Installation and Operation Instructions Trinity Ts 73 NOTES...
Страница 74: ...Trinity Ts Installation and Operation Instructions Ts Series 74 NOTES...
Страница 75: ...Ts Series Installation and Operation Instructions Trinity Ts 75 NOTES...