may be installed. Typically, auxiliary alarms are set
to sound for an unlimited amount of time.
Choose one of these options:
»
† 4 Minutes: The alarm siren shuts OFF after 4
minutes.
»
8 Minutes: The alarm siren shuts OFF after 8
minutes.
»
12 Minutes: The alarm siren shuts OFF after 12
minutes.
»
16 Minutes: The alarm siren shuts OFF after 16
minutes.
»
Unlimited Time: The alarm siren must be shut OFF
manually.
Q42: Trouble doesn’t sound at night
Prevents audible trouble alerts from waking users during
nighttime hours. When this feature is turned ON, audible
trouble alerts are suppressed between the precon
fi
gured
hours of 10:00 PM - 9:00 AM. This setting does not
suppress any other trouble alert features. The system
will continue to display trouble alert messages on the
touchscreen. It will also continue to transmit trouble reports
to the Central Station, as well as to log trouble alerts in the
system’s Alarm History.
If the reported trouble condition clears on its own or a
user acknowledges the condition(s) on the Control Panel
before 9:00 AM, no trouble tones will sound after 9:00 AM.
However, the trouble condition is recorded in the system’s
Alarm History.
Choose one of these options:
»
† Enabled: Turns the feature ON.
»
‡ Disabled: Turns the feature OFF. For compliance
with UL 985: Household Fire Warning System Units,
this setting must be disabled.
Q43: Z-Wave siren mode
Con
fi
gures the system to sound any Z-Wave sirens that
have been added to the network.
Choose one of the options:
»
† Sound for Burglary and Fire/CO: Con
fi
gures the
system to sound any connected Z-Wave sirens
during a burglary,
fi
re, or CO alarm.
»
Sound for Burglary Only: Con
fi
gures the system to
sound any connected Z-Wave sirens during burglary
alarms only.
Q44: Open collector #1 output
De
fi
nes output mode for the external device connected to
the OCL1 position of the GC3 Panel’s terminal block. See
“Control Panel Wiring Diagram.”
NOTE:
For compliance with ANSI/SIA CP-01-2010, you
must set Open Collector Output #1 to 11 - Follows Internal
Sounder Alarm.
NOTE:
If you enabled a keyfob auxiliary button to trigger
the GC3 Control Panel’s Open Collector #1, make sure this
question is set to 00 Disabled, “Program a Keyfob.”
Choose one of these options:
Q45: Open collector #2 output
De
fi
nes the output mode for the external device connected
to the OCL2 position of the GC3 Panel’s terminal block.
See “Control Panel Wiring Diagram.”
NOTE:
The factory default setting for
Open Collector
Output #2 is 00-Disabled
.
Choose on of these options: