![Nortek 2GIG GC3 Скачать руководство пользователя страница 56](http://html.mh-extra.com/html/nortek/2gig-gc3/2gig-gc3_installation-and-programming-manual_1705961056.webp)
Copyright © 2019 Nortek Security & Control LLC
56
Q10: Police emergency key
Con
fi
gures the system to respond in two (2) ways when a
user manually activates a panic alarm on the GC3 Panel.
The system can either be set to emit a loud, patterned
warning siren or to set off a silent panic alarm with no siren.
You can also disable the Panic button so that it is not visible
on the GC3 Panel.
Choose one of these options:
»
Disabled: Turns the feature OFF and hides the
Panic button from the Alarm screen.
»
† Audible: Turns the feature ON. This makes the
Panic button visible on the Alarm screen. The
system sounds a loud, patterned warning siren after
the user activates a panic alarm.
»
Silent Panic: Turns the feature ON. This makes
the Panic button visible on the Alarm screen. The
system sounds a silent panic alarm with no warning
siren after the user activates a panic alarm.
Q11: Fire emergency key
Con
fi
gures the system to show or hide the Fire button on
the Alarm screen of the GC3 Panel’s touchscreen. When
set to Audible, the button is visible and the system emits
a loud, patterned warning siren when a user manually
activates a
fi
re emergency alarm on the GC3 Panel.
Choose one of these options:
»
Disabled: Turns the feature OFF and hides the Fire
button from the Alarm screen.
»
† Audible: Turns the feature ON. This makes the
Fire button visible on the Alarm screen. The system
sounds a loud, patterned warning siren after the
user activates a
fi
re alarm.
Q12: Emergency key
Con
fi
gures the system to show or hide the Emergency
button on the Alarm screen of the GC3 Panel’s
touchscreen. When set to Audible, the button is visible and
the system emits a loud, patterned warning siren when a
user sets off an emergency alarm on the GC3 Panel.
Choose one of these options:
»
Disabled: Turns the feature OFF and hides the
Emergency button from the Alarm screen.
»
† Audible: Turns the feature ON. This makes the
Emergency button visible on the Alarm screen. The
system sounds a loud, patterned warning siren after
the user activates an emergency alarm.
Q13: Quick arming
Turns the system’s quick arming feature ON and OFF. This
feature can be assiged individually for each Smart Area.
(Smart Areas feature must be enabled (Q69) for settings for
S2-S4 to affect the system) When ON, any occupant can
arm the system. When OFF, only persons who know an
active, four-digit user code can arm the system.
Choose one of these options:
»
† Enabled: Turns the feature ON and does not
require occupants to enter a user code to arm the
system.
»
Disabled: Turns the feature OFF and requires
occupants to enter an active, four-digit user code to
arm the system.
Q14: Auto stay
Turns the system’s Auto Stay feature ON and OFF. This
feature can be assiged individually for each Smart Area.
(Smart Areas feature must be enabled (Q69) for settings
for S2-S4 to affect the system) When ON, the system
monitors the Exit Delay doors after the user arms the
system in Away Mode at the GC3 Panel. If no one exits that
door before the Exit Delay countdown expires, the system
automatically arms itself in Stay Mode. See “Q4: Exit delay,
in seconds (45-120).” This setting does not go into effect
when arming the system in Away Mode with a keyfob.
Choose one of these options:
»
† ‡ Enabled: Turns the feature ON. The system
monitors the Exit Delay door when the system is
armed and if no one exits the door before the Exit
Delay countdown expires, the system automatically
arms the system in Stay Mode. For compliance with
ANSI/SIA CP-01-2010, this feature is enabled by
default.
»
Disabled: Turns the feature OFF. The system arms
itself in Away Mode at the end of the Exit Delay
countdown.
Q15: Exit delay restart
Con
fi
gures the system to restart the Exit Delay countdown
if a user must re-enter the premises through an Exit Delay
door during the initial Exit Delay countdown. This feature
can be assiged individually for each Smart Area. (Smart
Areas feature must be enabled (Q69) for settings for S2-
S4 to affect the system) This is useful when a user arms
the system, exits the premises, and then needs to quickly
enter/exit the premises before the countdown expires. As
long as the user exits the premises during the Exit Delay
Restart countdown, there is no need to disarm and re-arm
the system. When this feature is turned ON, the Exit Delay
timer will restart one (1) time.
Choose one of these options:
»
† ‡ Enabled: Turns the feature ON. If the user exits
and then re-enters the premises before the Exit
Delay countdown expires, the Exit Delay countdown
restarts before the system is armed. For compliance
with ANSI/SIA CP-01-2010, this feature is enabled
by default
»
Disabled: Turns the feature OFF.
NOTE:
When the Exit Delay Restart feature is
enabled on the system and the user arms the