Choose one of these options:
»
30-240 Seconds: Choose a value between 30 and
240 seconds.
»
† ‡ 30 Seconds: For compliance with ANSI/SIA CP-
01-2010, the default Entry Delay 1 feature is set to
30 seconds.
Q6: Entry delay 2, in seconds (30-240)
Con
fi
gures the number of seconds for the Entry Delay 2
timer. Different times may be programmed for each Smart
Areas. (Smart Areas feature must be enabled (Q69) for
values for S2-S4 to affect the system) This speci
fi
es the
amount of time occupants have to disarm the system after
entering the premises through a door. Typically, secondary
entrances that require a slightly longer entry time are
programmed as an Exit/Entry 2 door. For example, a
back, side, or garage entry door. When a user enters the
premises while the system is armed, the Entry Delay 2
countdown starts.
The GC3 Panel beeps once every two (2) seconds during
the countdown.
Choose one of these options:
»
30-240 Seconds: Choose a value between 30 and
240 seconds.
»
†‡ 45 Seconds: For compliance with ANSI/SIA CP-
01-2010, the default Entry Delay 2 feature is set to
45 seconds.
Q7: Remote services provider
Con
fi
gures the appropriate Remote Services Provider for
the system. A Remote Services Provider is the third-party
security provider that powers the system’s interactive
services.
Choose one of these options:
»
None: Does not specify the provider.
»
† Alarm.com: Choose this option if the Remote
Services Provider is Alarm.com.
Q8: 2-way voice
Con
fi
gures the system to automatically turn the GC3
Panel’s 2-Way Voice feature ON or OFF after the type of
alarm you specify. This gives the GC3 Panel’s Cellular
Radio Module the ability to automatically dial the
Central Station and connect with an operator after an alarm
sounds. Once connected with the Central Station, people
on the premises can communicate with the operator using
the GC3 Panel’s built-in speaker and microphone.
Choose one of these options:
»
Disabled: Turns the feature OFF.
»
†Stay On Line: Turns the feature ON and
automatically enables the 2-Way Voice feature after
a burglary alarm.
»
Stay On Line, Including Fire & CO Alarms: Turns the
feature ON and automatically enables the 2-Way
Voice feature after a burglary,
fi
re, and/or carbon
monoxide alarm.
When the Control Panel connects with the operator, it will
beep once every six seconds. The beep alternates between
two tones and indicates the Control Panel is waiting for a
session command. If the operator fails to issue a command
withing three (3) minutes), the call is terminated. Once the
operator presses a command option, the beeps will stop
and a three (3)-minute audio session will start.
When two (2)-way voice communications have been
established, the Central Station operator can use the
following telephone keys to control the communications.
Each time the operator uses a command key, the session
is extended for three (3) additional minutes. During the last
minute of communications, the system beeps two (2) times
every 15 seconds to indicate that time is running out.
»
Tap 1 to enable Talk mode one (1)-way
communication from the Central Station to the
premises and allow the operator to talk.
»
Tap 2 to enable VOX mode two (2)-way
communications from the Central Station to the
premises.
»
Tap 3 to enable Listen mode one (1)-way
communication from the premises to the Central
Station.
»
Tap 7 to extend the session
fi
ve (5) minutes without
changing the mode of operation.
»
Tap 9 to end the audio session and terminate the
call.
Q9: Disable siren after two-way audio
Con
fi
gures the system to automatically turn the alarm siren
ON or OFF after the end of a 2-Way Voice session. For
this setting to take effect, “Q8: 2-way voice” above must be
enabled.
Choose one of these options:
»
Enabled: Choose this setting if you want the alarm
siren to remain OFF after a 2-Way Voice session
ends.
»
† Disabled: Choose this setting if you want the
alarm siren to resume after a 2-Way Voice session
ends.
NOTE:
When set to disabled, the alarm siren will
only resume after a 2-way voice session when the
corresponding alarm bell cutoff time has not expired.
See “Q40: Burglary bell cutoff time” and “Q41: Fire
bell cutoff time.”