![Nortek 2GIG GC3 Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/nortek/2gig-gc3/2gig-gc3_installation-and-programming-manual_1705961027.webp)
Copyright © 2019 Nortek Security & Control LLC
27
Control Panel Wiring Diagram
The following diagram shows the Control Panel wiring.
Control Panel Wiring Diagram
ALL output
voltages are
Class 2
Terminal 1 only
provides power when
the Control Panel’s
power supply is
connected to an
AC power source
CONTROL
PANEL
1 – 14VDC Power Input (+)
2 – 14VDC Power Input (–)
3 – COM
4 – Bell (+)
5 – Bell (–)
6 – ZONE 1
7 – ZONE 2
8 – COM
OBSERVE POLARITY
when connecting the
Power Supply
Plug-in 14 VDC
1.7 AMP
Switching
Power Supply
Piezo
Siren
Supervised
Bell Output
14 VDC
@ 500 mA
Maximum
2.2 K
Normally
Closed
Contact
2.2 K
Normally Closed
Contact
UL NOTE: Wiring for
all wired sensors
and annunciators
must use UL Listed
low voltage Class 2
or better grade wire.
Sensor and display
voltages must comply
with Class 2 low
voltage requirements
End-of-Line
Resistors
are
optional
on
hardwire
loops
Open
Collector
Output
250 mA
@ 16 VDC
Maximum
Example
hookup
showing
an armed
LED. The
Open Colector
output can be
programmed
to activate
during various
conditions.
1 K
LED
1
2
3
4
5
6
7
8