Operation
A 5-4
Part 331235C
E
2003 Nordson Corporation
Part A: System Overview
Initial Gun Use
Perform this procedure when a gun is first put into service.
1. Make sure that the maximum kV setting (95 kV Sure Coat guns; 100 kV
Versa-Spray guns) appears on the digital display in the STD mode with
the AFC function on.
2. See Figure A 5-2. Press the VIEW key (4) to display
A.
3. Trigger the gun and obtain the desired spray pattern by adjusting the
flow rate and atomizing air pressures.
4. Record the
A output with no parts in front of the gun.
5. Monitor the
A output daily, under the same conditions. A significant
increase in
A output indicates a probable short in the gun resistor. A
significant decrease indicates a failing resistor or voltage multiplier.
1400868A
2
1
8
11
4
5
7
9
3
6
10
12
Figure A 5-2
Modular Gun Control System Operation
1. Gun select key
2. Gun trigger key
3. Trigger LED
4. VIEW key
5. Select Charge key
6. Display
7. SET ALL key
8. +/– keys
9. ALL key
10. Local
11. Gun group trigger keys
12. PGM key
Содержание Sure Coat
Страница 6: ...Table of Contents ii Part 331235C E 2003 Nordson Corporation Part A System Overview...
Страница 14: ...Safety A 1 4 Part 331235C E 2003 Nordson Corporation Part A System Overview...
Страница 34: ...Installation A 3 6 Part 331235C E 2003 Nordson Corporation Part A System Overview...
Страница 52: ...Operation A 5 12 Part 331235C E 2003 Nordson Corporation Part A System Overview...
Страница 64: ...Troubleshooting A 6 12 Part 331235C E 2003 Nordson Corporation Part A System Overview...