Configuration
A 4-6
Part 331235C
E
2003 Nordson Corporation
Part A: System Overview
Set Point Lockout
The ability for the operator to adjust electrostatic set points and operating
mode changes may be enabled or disabled using the following procedure.
NOTE:
When the set point adjustment is locked out, the operator can only
use the central control unit to trigger the guns, enter the diagnostics mode,
purge, and switch between F1 and F2 air pressure settings.
1. Enter the configuration mode. Refer to
Entering Configuration Mode
for
instructions.
2. See Figure A 4-1. Press the ALL key (10). DENY CHANGE scrolls
across, then either 0 or 1 appears the display (8).
3. Use the +/– keys (9) to select one of the following settings as desired.
S
0:
Enabled. Operator may adjust set points to fit application.
S
1:
Disabled. Operator-specified set points are active and cannot be
changed.
NOTE:
To continue on to another configuration mode, press the
corresponding configurable option key. Configurable option keys are
indicated by blinking LEDs.
4. To exit the set point lockout mode, press the Nordson key (15).