Part A: System Overview
Grounding
WARNING:
Operating faulty electrostatic equipment is hazardous and can
cause electrocution, fire, or explosion. Make resistance checks part of your
periodic maintenance program. If you receive even a slight electrical shock
or notice static sparking or arcing, shut down all electrical or electrostatic
equipment immediately. Do not restart the equipment until the problem has
been identified and corrected.
All work conducted inside the spray booth or within 1 m (3 ft) of booth
openings is considered within a Class 2, Division 1 or 2 Hazardous location
and must comply with NFPA 33, NFPA 70 (NEC articles 500, 502, and 516),
and NFPA 77, latest conditions.
S
All electrically conductive objects in the spray areas shall be electrically
connected to ground with a resistance of not more than 1 megohm as
measured with an instrument that applies at least 500 volts to the circuit
being evaluated.
S
Equipment to be grounded includes, but is not limited to, the floor of the
spray area, operator platforms, hoppers, photoeye supports, and
blow-off nozzles. Personnel working in the spray area must be
grounded.
S
There is a possible ignition potential from the charged human body.
Personnel standing on a painted surface, such as an operator platform,
or wearing non-conductive shoes, are not grounded. Personnel must
wear shoes with conductive soles or use a ground strap to maintain a
connection to ground when working with or around electrostatic
equipment.
S
Operators must maintain skin-to-handle contact between their hand and
the gun handle to prevent shocks while operating manual electrostatic
spray guns. If gloves must be worn, cut away the palm or fingers, wear
electrically conductive gloves, or wear a grounding strap connected to
the gun handle or other true earth ground.
S
Shut off electrostatic power supplies and ground gun electrodes before
making adjustments or cleaning powder spray guns.
S
Connect all disconnected equipment, ground cables, and wires after
servicing equipment.
Action in the Event of a Malfunction
If a system or any equipment in a system malfunctions, shut off the system
immediately and perform the following steps:
S
Disconnect and lock out electrical power. Close pneumatic shutoff
valves and relieve pressures.
S
Identify the reason for the malfunction and correct it before restarting the
equipment.
Disposal
Dispose of equipment and materials used in operation and servicing
according to local codes.
Содержание Sure Coat
Страница 6: ...Table of Contents ii Part 331235C E 2003 Nordson Corporation Part A System Overview...
Страница 14: ...Safety A 1 4 Part 331235C E 2003 Nordson Corporation Part A System Overview...
Страница 34: ...Installation A 3 6 Part 331235C E 2003 Nordson Corporation Part A System Overview...
Страница 52: ...Operation A 5 12 Part 331235C E 2003 Nordson Corporation Part A System Overview...
Страница 64: ...Troubleshooting A 6 12 Part 331235C E 2003 Nordson Corporation Part A System Overview...