Part A: System Overview
Controls and Indicators
(contd)
Table A 2-2 Front Panel Controls and Indicators
(contd)
Item
Component
Description
9
VIEW Key
Selects the display of gun current or gun voltage when the
corresponding gun is triggered.
Selects the display of gun current, voltage, or trigger hours
while the corresponding gun is not triggered.
Values appear on the gun’s bar graph and the digital display.
The maintenance timer cannot be viewed while the gun is
triggered.
10
AFC Key
Turns on and off the AFC function.
11
STD Key
Turns on and off the standard mode.
12
SELECT CHARGE Key
Turns on and off the various Select Charge modes.
13
Display
Refer to
Display
in this section.
14
SET ALL Key
Allows the operator to adjust set points of all like guns in the
system at the same time.
15
+ Key
Increases the set point value. Pressing the button
continuously causes the value to increase until the maximum
value is reached.
16
−
Key
Decreases the set point value of the selected gun. Pressing
the button continuously causes the set point value to decrease
until the minimum value is reached.
17
Gun Type LEDs
Indicates the type of gun (IPS or Tribomatic) connected to the
system.
18
Group Triggering Keys
Allows the operator to set up and trigger gun groups.
PGM: Activates the program mode so that guns may be put in
groups.
A, B, C, D: Triggers an individual group of guns.
ALL: Simultaneously triggers all guns in the system.
19
LOCAL Key
If applicable, switches system control from the central control
unit to the application/triggering controller or remote PLC. The
central control unit has control of system when the LOCAL
LED is lit.
20
F1/F2 Key
Flow 1/Flow 2 Systems Only:
Switches from flow rate 1 to
flow rate 2 air pressure setting.
21
PURGE Keys
GUN: Purges the powder paths of all of the guns in the
system
SYST: Not used
NOTE:
The GUN key is only functional in systems with the
gun purge module.
22
Nordson Key
Puts the system into the diagnostics mode to view error codes.
23
A Display LEDs
Indicates which bar graph scaling option is currently active.
24
A Key
Switches the scaling of the gun bar graphs. The total bar
graph range can be either 50 or 100
A for IPS; or 5 or 10
A
for Tribomatic guns.
Содержание Sure Coat
Страница 6: ...Table of Contents ii Part 331235C E 2003 Nordson Corporation Part A System Overview...
Страница 14: ...Safety A 1 4 Part 331235C E 2003 Nordson Corporation Part A System Overview...
Страница 34: ...Installation A 3 6 Part 331235C E 2003 Nordson Corporation Part A System Overview...
Страница 52: ...Operation A 5 12 Part 331235C E 2003 Nordson Corporation Part A System Overview...
Страница 64: ...Troubleshooting A 6 12 Part 331235C E 2003 Nordson Corporation Part A System Overview...