Operation
A 5-3
Part 331235C
E
2003 Nordson Corporation
Part A: System Overview
Startup
1. Make sure that the following conditions are met before starting up the
modular gun control system:
S
The booth exhaust fans are on.
S
The powder recovery system is operating.
S
The powder in the feed hopper is thoroughly fluidized.
S
The gun cable, feed hose, and air tubing are correctly connected to
the gun, pump, and modular gun control system.
NOTE:
If the control system is wired to the booth electrical panel, you may
leave the control system power switches in the on position. The control
system will automatically turn on and off when the booth power is turned on
and off.
2. Turn on the modular gun control system by turning its two power
switches to the on position. There is one switch on the back of the main
control cabinet and one on the back of the central control unit. Make
sure that all the icons on the display light.
NOTE:
The system performs an internal check for 5 seconds. The
controller switches to either the factory default mode or to the last selected
mode.
1400867A
Figure A 5-1
Typical Display in STD Mode with Gun Not Triggered
3. Turn on the main air supply and set the operating air pressures to the
appropriate settings.
NOTE:
The pressures given are average starting points. Pressures
vary according to required film build, line speed, and part configuration.
Refer to the
Operation
section in Part B,
Pneumatic Modules
, for air
pressure adjustment guidelines.
S
Atomizing Air:
1 bar (15 psi)
S
Flow Rate Air:
2 bar (30 psi)
4. If you have added or replaced a gun since the last time you operated the
system, perform the
Initial Gun Use
procedure.
5. Perform the
Daily Operation
procedure.
Содержание Sure Coat
Страница 6: ...Table of Contents ii Part 331235C E 2003 Nordson Corporation Part A System Overview...
Страница 14: ...Safety A 1 4 Part 331235C E 2003 Nordson Corporation Part A System Overview...
Страница 34: ...Installation A 3 6 Part 331235C E 2003 Nordson Corporation Part A System Overview...
Страница 52: ...Operation A 5 12 Part 331235C E 2003 Nordson Corporation Part A System Overview...
Страница 64: ...Troubleshooting A 6 12 Part 331235C E 2003 Nordson Corporation Part A System Overview...