Operation
A 5-9
Part 331235C
E
2003 Nordson Corporation
Part A: System Overview
Set Point Adjustments
See Figure A 5-2. You can adjust the operating modes and set points of
either a single gun or all guns in the system at the same time.
Adjustment
Procedure
Single Gun
1. Press the gun select key (1) of the gun you want to adjust. The LED to the
left of the gun select key will illuminate.
2. Adjust the operating modes and set points as desired.
3. Press the gun’s trigger key (2) to test the spray pattern.
All Guns in System
(SET ALL)
NOTE:
Different types of guns (Tribomatic, Versa-Spray, and Sure Coat)
cannot be simultaneously adjusted using SET ALL.
1. Press the gun select key (1) of the gun that you want to all other guns to
match.
2. Press the SET ALL key (7). The SET ALL LED lights.
3. Adjust the control mode and AFC set points to the desired settings. All like
guns in the system will be adjusted to the same control mode and AFC set
points in real time.
4. Press the SET ALL key to exit the SET ALL mode.
5. Press the ALL key (9) to test the spray patterns.
Setting Up Groups of Guns
The central control unit can be programmed to trigger an operator-specified
group of guns at the same time. The central control unit can store up to four
groups of guns.
The guns in each of these groups can be triggered simultaneously by
pressing the corresponding A, B, C, or D key. For example, guns in the first
slot may be located in group A; guns in the second slot may be located in
group B; etc.
1. See Figure A 5-2. Press the PGM key (12). The PGM LED lights.
2. Press the group trigger key (11) to which you want to assign guns. The
corresponding LED lights and the letter appears on the display (6).
3. Press the gun trigger keys (2) for the guns that you want to assign to the
group. The corresponding trigger LEDs (3) will light. If you want to
remove a gun from the group, press the corresponding gun trigger key.
NOTE:
A single gun may be assigned to up to four groups.
4. Repeat steps 2 and 3 to program additional groups of guns.
5. Press the PGM key when you have finished programming the desired
groups of guns.
6. Press the gun group trigger key to make sure that the guns that you
have just programmed trigger.
Содержание Sure Coat
Страница 6: ...Table of Contents ii Part 331235C E 2003 Nordson Corporation Part A System Overview...
Страница 14: ...Safety A 1 4 Part 331235C E 2003 Nordson Corporation Part A System Overview...
Страница 34: ...Installation A 3 6 Part 331235C E 2003 Nordson Corporation Part A System Overview...
Страница 52: ...Operation A 5 12 Part 331235C E 2003 Nordson Corporation Part A System Overview...
Страница 64: ...Troubleshooting A 6 12 Part 331235C E 2003 Nordson Corporation Part A System Overview...