6
EN
Controller
1
2
3
4
5
6
7
8
9
0
a
Name
Function
1
[WORK] LED
Green flashing: “Workpiece setup time” (No.14 WORK-S-T), for input of workpiece signal, in progress
Green lighted: Electric screwdriver in operation (rotation) enabled state
Unlighted: Electric screwdriver in non-operation (rotation) state
2
[CRT-T] LED
Orange flashing: When the current screw fastening time is at “screw fastening time lower limit
value” (No.15 CRT-T-L) or less
Orange lighted: When current screw fastening time is within the screw fastening time upper/lower
limit values (screw tightening OK range)
Orange lighted then unlighted: When the current screw fastening time is at “screw fastening time
upper limit value” (No.16 CRT-T-U) or more
3
[FSTN-T] LED
Yellow lighted: In “HARD” fastening setting, when moved to seated speed
Yellow flashing: Screw fastening time (MEAS-T) measurement in progress
4
[CH 1] LED
[CH 2] LED
[CH 3] LED
[CH 4] LED
Red lighted: When the respective operations channels are selected
5
[WORK RESET]
button
If pressed for 1 second during screw fastening mode, the count is reset to the start, or the
operations channel returned back by 1.
6
[MANUAL] button If pressed for 1 second during screw fastening mode, transits to manual mode.
7
[C-UP / F-NG]
LED
Blue lighted: Lights up when screw tightening ends normally
Red lighted: Lights up when screw tightening was NG
8
[OK / NG] LED
Green lighted: When screw fastening operation has completed the set count, and operation was OK
Red lighted: When workpiece has been removed during screw fastening operation, and operation
was NG
9
[COUNT] LED
Displays in count down the screw fastening number (count).
0
LCD
Displays the set content or state.
a
[SETTING] dial
Dial for the push switch embedded setting.
Push operation: Determines transition to the setting mode, and the setting item and setting value
Rotation operation: Changes the setting item and setting value
Part Names