22
EN
7 Basic Settings
Operation mode
The tool can be set to handle various screw tightening.
You can enter each mode from the screw fastening mode.
For details on operation and the operation of each function, see the reference page.
Mode
Operation
Operation to return to screw fastening mode Reference
Setting mode
Press and hold the [SETTING] dial
Press and hold the [SETTING] dial
p. 22
Screw count reset
In count down state, press and hold
the [WORK RESET] button
Return automatically
p. 44
Operations channel
return
In count set value state, press and
hold the [WORK RESET] button
Return automatically
p. 44
Operations channel
switching
(during INPUT setting)
Channel A/B input signal ON
Return automatically
p. 45
External input signal
startup
Forward rotation startup/Reverse
rotation startup input signal ON
Return automatically
p. 45
Count return mode
(during ON2 setting)
With the changeover switch in the
reverse rotation side state, press the
[SETTING] dial
After reverse rotation: Return
automatically
Or changeover switch operation
p. 33
Controller button
operation lock/release
Key lock input signal ON/OFF
Return automatically
p. 46
Manual mode
Press and hold the [MANUAL] button
Press and hold the [MANUAL] button
p. 21
Setting mode operation
CAUTION
z
z
Always record the set values. Utilize “Setting memo” (p. 63).
If the tool fails, all settings may be initialized. Also, settings may be initialized at the time of repair in order to
check operation.
Please note that there is no function to output the set values to an outside device.
1
In screw fastening mode, press and hold the [SETTING] dial
The mode enters setting mode.
2
Rotate the [SETTING] dial, and display the item to
change
The setting item is displayed in the 1st line on the LCD, and
No. flashes.
If [WORK RESET] button is pressed and held while No. is
flashing, it returns to the operations mode without changing
the setting.
Flashes
3
Press the [SETTING] dial
The set values of the displayed setting item can now be changed.
4
Rotate the [SETTING] dial, and change the value
The value selected flashes.
If [WORK RESET] button is pressed while the value is
flashing, it returns to Step 2 without changing the setting.
Flashes
TV07783-1_DLV10C_en.indb 22
2017/06/27 17:41:37