18
EN
Screw fastening mode
The [CH 1] to [CH 4] LED lights up in red, and the setting torque and speed are displayed on the LCD. The screw
fastening count is displayed on the [COUNT] LED and the [WORK] LED lights in green. When operation (rotation) is
possible, this status is called “screw fastening mode.”
72548(62)7
63(('PLQ
Lights in green
Screw count
Setting torque
speed
Lights in red
Changeover switch
CAUTION
z
z
Do not operate the changeover switch while the tool is rotating. Doing so could cause a failure.
z
z
When the tool is not used, set the switch to neutral position.
z
z
Do not apply a shock (such as dropping) or excessive load to the changeover switch. Doing so could cause a
failure.
By sliding the changeover switch, you can change the rotation direction of the electric screwdriver.
“
¡
” means neutral. The electric screwdriver does not rotate.
Neutral
Forward rotation:
Rightward rotation at set speed
(rotates clockwise)
Reverse rotation:
Leftward rotation at maximum
speed (rotates counterclockwise)
If started by external input signal, the changeover switch position is invalid.
Basic Operation
TV07783-1_DLV10C_en.indb 18
2017/06/27 17:41:36