41
EN
Timing of I/O signal
Terminal
No.
Input signal
Signal timing
Remarks
3
Channel A
ON
OFF
While the input signal is ON, channel A/B
is ON
4
Channel B
5
Forward rotation startup
While the input signal is ON, electric
screwdriver is active (rotates)
6
Reverse rotation startup
7
WORK
While the input signal is ON, the workpiece
signal is ON
8
WORK RESET
With input signal 1 sec. ON, WORK
RESET is ON
9
Keylock
While input signal is ON, controller button
operation is locked
Terminal
No.
Output signal
Signal timing
Remarks
11
Forward rotation signal
ON
OFF
During forward rotation/reverse rotation,
ON
12
Reverse rotation signal
13
Count-up (C-UP)
ON
OFF
During normal torque-up, ON for 0.3 sec.
14
Screw fastening NG (F-NG)
During screw fastening NG, ON for 0.3
sec.
15
Operations channel 1 (CH1)
ON
OFF
Channel is ON during operations, during
settings
16
Operations channel 2 (CH2)
17
Operations channel 3 (CH3)
18
Operations channel 4 (CH4)
19
Operations OK (OK)
ON
OFF
When the OK signal is output, ON for 0.3
sec.
Or until the workpiece is removed, ON
(See “OK output timing” (p. 33))
20
Operations NG (NG)
ON
OFF
During Operations NG, ON
TV07783-1_DLV10C_en.indb 41
2017/06/27 17:41:41