11.2 Basics
WF1967/WF1968
11-5
c) Intra-step parameter change pattern
Intra-change parameters, except for the waveform, have the following three patterns of value
changes within the step. These are called action settings. In case of waveform parameters, there is
no action setting. Instead, the setting is always done in that step.
• Constant [Const]
The value is fixed to that setting specified in the step.
• Keep [Keep]
The value immediately before the move to that step is maintained. This means, the value changes
according to the status of the previous step.
When the action setting is set to [Keep], you will not be able to perform a set of parameter values.
• Sweep [Sweep]
The value changes linearly over the step time from the value immediately before the move to that
step to the value set in that step. This means, after the lapse of the step time in that step, the value
reaches the set value. The starting value changes according to the status of the previous step.
d) Phase at sequence mode
In the sequence oscillation, the reference phase is generated internally, the value set in the reference
phase in the phase [Phase] will be output are added. Reference phase, frequency / amplitude / offset
/ phase changes in a continuous even if the change. Also, except for DC and noise, even if the
waveform changes and changes continuously. Immediately after output DC and noise will be the
reference phase resumes from 0 degree.
Action
settings
Parameter change when the action
of the next step is Const
Parameter change when the action
of the next step is Keep
Parameter change when the action
of the next step is Sweep
Previous step
Previous step
Previous step
Next step
Next step
Next step
Setting value
Setting value
The value is the setting
value for the next step
The final value of the
previous step is kept
The value changes from the final
value of the previous step to the
setting value of the next step
step N
step
N+1
step
N+2
step
N+3
step
N+4
step
N+6
step
N+5
Fctn=DC
reference phase
(internal signal)
output signal
frequency
changes
phase
changes
amplitude
changes
change to
DC (or
noise)
change to
except DC
and noise
Reference phase is continuous even if frequency, amplitude,
DC offset, waveform (except DC and noise) are changed.
Reference phase
restart from 0° after
DC or noise.
Содержание WAVE FACTORY WF1967
Страница 1: ...MULTIFUNCTION GENERATOR WF1967 WF1968 Instruction Manual Operations NF Corporation nbn Austria GmbH...
Страница 2: ......
Страница 3: ...MULTIFUNCTION GENERATOR WF1967 WF1968 Instruction Manual Operations DA00048287 002...
Страница 4: ......
Страница 10: ...WF1967 WF1968 vi...
Страница 19: ...WF1967 WF1968 1 1 1 Overview 1 1 Features 1 2 1 2 Operating Principles 1 4...
Страница 50: ...3 3 Cautions on Floating Ground Connection WF1967 WF1968 3 20 MEMO...
Страница 156: ...4 9 Setting and Operation of Burst WF1967 WF1968 4 106 MEMO...
Страница 206: ...7 9 Identifying Memory Space Required for Saving Arbitrary Waveforms WF1967 WF1968 7 14 MEMO...
Страница 221: ...WF1967 WF1968 9 1 9 Synchronizing Multiple Units 9 1 Connection Procedure 9 2 9 2 Performing Synchronization 9 4...
Страница 226: ...9 2 Performing Synchronization WF1967 WF1968 9 6 MEMO...
Страница 262: ...13 6 Product Information Display Information WF1967 WF1968 13 4 MEMO...
Страница 274: ...14 7 Suspected Failure WF1967 WF1968 14 12 MEMO...
Страница 275: ...WF1967 WF1968 15 1 15 Maintenance 15 1 Outline 15 2 15 2 Operation Inspection 15 4 15 3 Performance Test 15 5...
Страница 286: ...15 3 Performance Test WF1967 WF1968 15 12 MEMO...
Страница 287: ...WF1967 WF1968 16 1 16 List of Initial Settings...
Страница 326: ......
Страница 328: ......
Страница 329: ......