10.5 AC Output
DP Series
245
10.5 AC
Output
[V]=Vrms, [A]=Arms, and the power supply input voltage is 200 V, unless otherwise noted.
Single-phase model and Single-phase output of Multi-phase model
015S 030S
045S
045M
060S 075S
090S
090M
105S 120S
Mode Single-phase
two-wire
Floating output, the Lo terminal can be grounded.
Rated output
voltage
100 V / 200 V
Voltage setting
range
0.0 V to 155.0 V / 0.0 V to 310.0 V
0.0 Vp-p to 440.0 Vp-p / 0.0 Vp-p to 880.0 Vp-p (arbitrary wave)
Setting
resolution
0.1 V
Voltage accuracy *1
±
(1% of set + 0.6 V / 1.2 V)
Maximum current
*2
15 A /
7.5 A
30 A /
15 A
45 A /
22.5 A
60 A /
30 A
75 A /
37.5 A
90 A /
45 A
105 A /
52.5 A
120 A /
60 A
Maximum peak
current
*3
Peak value which is four times of the maximum current (Apk)
Power capacity
*4
1.5 kVA 3 kVA 4.5 kVA
6 kVA
7.5 kVA
9 kVA 10.5 kVA 12 kVA
Load power factor
0 to 1 (phase lead or phase lag, 45 Hz to 65 Hz, external power injection and
regeneration are not available.)
Frequency setting
range
40 Hz to 550 Hz (AC mode)
1 Hz to 550 Hz (AC+DC mode)
Setting
resolution
0.1 Hz
Frequency accuracy
±
0.01% of set (23 °C
±
5 °C)
Frequency stability
*5
±
0.005%
Voltage frequency
characteristic
*6
±
1%
Output waveform
sine wave, arbitrary wave (16 types), clipped sine wave (3 types)
Output on phase
0.0°
to 359.9° variable (setting resolution 0.1°)
Output off phase
0.0°
to 359.9° variable (setting resolution 0.1°, active/inactive selectable)
DC offset *7
Within
±
20 mV (typ. fine adjustment available)
*1: In the case of 10 V to 150 V/20 V to 300 V, sine wave, no load, 45 Hz to 65 Hz, DC voltage
setting 0 V, 23 °C
±
5 °C.
*2: If the output voltage is higher than the rated value, this is limited (lowered) to satisfy the power
capacity. If there is the DC superimposition, the active current of AC+DC satisfies the
maximum current. In the case of 40 Hz or lower or 400 Hz or higher, and that the ambient
temperature is 40°C or higher, the maximum current may decrease.
*3: For the capacitor input type rectified load (crest factor=4), the rated output voltage, and 45 Hz
to 65 Hz.
*4: In the case that the power input is 170 V or lower, models with 6 kVA or higher have the limit
on the power capacity.
*5: For 45 Hz to 65 Hz, the rated output voltage, no load and the resistance load for the maximum
current, and the operating temperature.
*6: For 40 Hz to 550 Hz, sine wave, the rated output voltage, the resistance load for the maximum
current at 55 Hz, and 55 Hz reference.
*7: In the case of the AC mode and 23°C
±
5°C.
Содержание DP015S
Страница 1: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL NF Corporation ...
Страница 2: ......
Страница 3: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL DA00027113 001 ...
Страница 4: ......
Страница 18: ......
Страница 19: ...DP Series 1 1 Outline 1 1 Overview 2 1 2 Series Line up and Polyphase System Configuration 2 1 3 Features 4 ...
Страница 24: ...1 Outline PROGRAMMABLE AC POWER SOURCE 6 ...
Страница 215: ...DP Series 197 5 Description of Screen and Menu 5 1 Screen Configuration 198 5 2 Menu Composition 202 ...
Страница 224: ...5 Description of Screen and Menu PROGRAMMABLE AC POWER SOURCE 206 ...
Страница 225: ...DP Series 207 6 Remote Control 6 1 Communication Interface 208 6 2 Remote Local State Switching 214 ...
Страница 237: ...7 8 Replacement Air Filter DP Series 219 フロントグリル フロントグリル Front grill 1 Front grill 2 Figure 7 2 Front Grills ...
Страница 238: ...7 Options PROGRAMMABLE AC POWER SOURCE 220 ...
Страница 239: ...DP Series 221 8 Troubleshooting 8 1 Error Messages and Error Handling 222 8 2 When a Failure is Suspected 229 ...
Страница 298: ......
Страница 300: ......
Страница 302: ......
Страница 303: ......
Страница 304: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima Higashi Kohoku ku Yokohama 223 8508 JAPAN ...