10. Specifications
PROGRAMMABLE AC POWER SOURCE
246
Polyphase model and Polyphase output of Multi-phase model
030D
045M
060D
090M
090D 120D 045T
045M
090T
090M
Single-phase three-wire
Three-phase four-wire
(Y-connection)
Mode
Floating output, the N terminal can be grounded.
Setting mode
Balanced mode, Unbalanced mode
Rated output voltage
(Phase voltage)
100 V / 200 V
Phase voltage setting (for all phases in balanced mode and each phase in
unbalanced mode)
0.0 V to 155.0 V / 0.0 V to 310.0 V
0.0 Vp-p to 440.0 Vp-p / 0.0 Vp-p to 880.0 Vp-p (arbitrary wave)
Line voltage setting (balanced mode and sine wave only)
Voltage setting range
0.0 V to 310.0 V / 0.0 V to 620.0 V
0.0 V to 268.4 V /
0.0 V to 536.8 V
Setting resolution
Phase voltage setting: 0.1 V, Line voltage setting: 0.2 V
Voltage accuracy
(Phase voltage)
*8
±
(1% of set + 0.6 V / 1.2 V)
Maximum current
(Phase current)
*9
15 A /
7.5 A
30 A /
15 A
45 A /
22.5 A
60 A /
30 A
15 A /
7.5 A
30 A /
15 A
Maximum peak
current
(phase current) *10
Peak value which is four times of the maximum current (Apk)
Power capacity
*11
3 kVA
6 kVA
9 kVA
12 kVA
4.5 kVA
9 kVA
load power factor
0 to 1 (phase lead or phase lag, 45 Hz to 65 Hz, external power injection
and regeneration are not available.)
Frequency setting
range
40 Hz to 550 Hz (AC mode)
1 Hz to 550 Hz (AC+DC mode)
Setting resolution
0.1 Hz
Frequency accuracy
±
0.01% of set (23 °C
±
5 °C)
Frequency stability
*12
±
0.005%
Voltage frequency
characteristic
*13
±
1%
Output waveform
sine wave, arbitrary wave (16 types), clipped sine wave (3 types)
Output on phase *14
0.0°
to 359.9° variable (setting resolution 0.1°)
Output off phase *14 0.0°
to 359.9° variable (setting resolution 0.1°, active/inactive selectable)
Setting range of the
phase angle
(Unbalanced mode)
L2 phase: 180.0°
±
35.0°
L2 phase:
120.0°
±
35.0°
L3 phase:
240.0°
±
35.0°
Setting
resolution
0.1°
Phase angle accuracy
*15
45 Hz to 65 Hz:
±
1.0°
40 Hz to 550 Hz:
±
2.0°
DC offset *16
Within
±
20 mV (typ. fine adjustment available)
*8: In the case of 10 V to 150 V/20 V to 300 V, sine wave, no load, 45 Hz to 65 Hz, 23 °C
±
5 °C.
*9: If the output voltage is higher than the rated value, this is limited (lowered) to satisfy the power
capacity. In the case of 40 Hz or lower or 400 Hz or higher, and that the ambient temperature is
40°C or higher, the maximum current may decrease.
Содержание DP015S
Страница 1: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL NF Corporation ...
Страница 2: ......
Страница 3: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL DA00027113 001 ...
Страница 4: ......
Страница 18: ......
Страница 19: ...DP Series 1 1 Outline 1 1 Overview 2 1 2 Series Line up and Polyphase System Configuration 2 1 3 Features 4 ...
Страница 24: ...1 Outline PROGRAMMABLE AC POWER SOURCE 6 ...
Страница 215: ...DP Series 197 5 Description of Screen and Menu 5 1 Screen Configuration 198 5 2 Menu Composition 202 ...
Страница 224: ...5 Description of Screen and Menu PROGRAMMABLE AC POWER SOURCE 206 ...
Страница 225: ...DP Series 207 6 Remote Control 6 1 Communication Interface 208 6 2 Remote Local State Switching 214 ...
Страница 237: ...7 8 Replacement Air Filter DP Series 219 フロントグリル フロントグリル Front grill 1 Front grill 2 Figure 7 2 Front Grills ...
Страница 238: ...7 Options PROGRAMMABLE AC POWER SOURCE 220 ...
Страница 239: ...DP Series 221 8 Troubleshooting 8 1 Error Messages and Error Handling 222 8 2 When a Failure is Suspected 229 ...
Страница 298: ......
Страница 300: ......
Страница 302: ......
Страница 303: ......
Страница 304: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima Higashi Kohoku ku Yokohama 223 8508 JAPAN ...