background image

3-Phase Switched PDU, 8.6 kW, 24 208V outlets
(21-C13, 3-C19) 10-ft. Cord, NEMA L15-30P 30A
input, 0U vertical mount

MODEL NUMBER: 

PDU3VSR10L1530

 

 

 

Description

Tripp Lite 3 phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with

the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical

conditions and remotely monitor output power consumption per-phase or per-receptacle. PowerAlert interface

supports remote control and custom notification of user-specified conditions via email, secure web, SNMP,

Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot

unresponsive network hardware, or be custom programmed for user-defined power-up and power-down

sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as

network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the

connection of unauthorized hardware. PDU output current consumption in amps per-phase or per-receptacle can

be displayed locally via visual meter or remotely via web/network interface to warn of potential overloads before

critical IT mains or branch breakers trip. 

Features

8.6kW 3 phase 208V Switched Power Distribution Unit / PDU with built-in web/network interface

Attached NEMA L15-30P 30A (3P+E) 208V 3 phase input; 10 ft. / 3m cord

0U, 70 inch / 178cm vertical form factor 

24 switched 208V outlets (21 C13, 3 C19) in 3 single phase load banks

Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis

Enables reboot of locked equipment, custom power-on/power-off sequences, load-shedding of optional loads and disabling unused outlets

Network interface provides PDU control and data regarding input voltage, per-outlet and per-phase load levels

Digital display with scroll-buttons supports per-outlet or per-phase load levels, IP-address self-identification and 180 degree display rotation

Supports user-specified alarm notification thresholds

In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH

door sensors

Highlights

Switched 8.6kW 3 Phase 208V

PDU; 70 in. / 178cm 0U vertical

rackmount

Reports voltage, frequency &

load per-outlet or phase via

ethernet interface

Visual current meter; Toolless

button-mount installation

NEMA L15-30P 30A (3P+E) 208V

3 phase input; 10 ft. / 3m line

cord

21 C13 & 3 C19 single phase

switched outlets with cord

retention brackets

Temperature, humidity and

contact closure monitoring options

Applications

Ideal for 3 phase network

configurations in datacenters and

heavily configured equipment

racks

Package Includes

Switched rackmount PDU with

pre-installed mounting buttons

Plug retention plates

 Spare installation buttons (2

9mm / 4 6mm) 

Rack mounting brackets

Owner's manual